Summary of Contents for Extron electronics MMX 32 VGA A
Page 1
User’s Manual MMX 32 VGA A Mini Matrix Switcher Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia Extron Electronics, Japan 68-789-01 Rev. D 1230 South Lewis Street Beeldschermweg 6C 135 Joo Seng Rd. #04-01 Kyodo Building, 16 Ichibancho Anaheim, CA 92805 3821 AH Amersfoort, The Netherlands PM Industrial Bldg., Singapore 368363...
Page 2
Precautions Safety Instructions • English FCC Class A Notice Warning This symbol is intended to alert the user of important Power sources • This equipment should be operated only from the power source indicated on the product. This equipment is intended to be used with a main operating and maintenance (servicing) instructions Note: This equipment has been tested and found to comply with the limits for a power system with a grounded (neutral) conductor.
Using the help system ............3-13 Contact Closure Control ........... 3-13 Connecting an MMX 32 AAP or MMX 32 MAAP Control Panel ............... 3-14 ..........3-14 Input selection connector ............. 3-15 Tally power connector MMX 32 VGA A • Table of Contents...
............A-5 All trademarks mentioned in this manual are the properties of their respective owners. 68-789-01 Rev. D 01 07 Chapter One Introduction About this Manual About the MMX 32 VGA A Features MMX 32 VGA A • Table of Contents...
The user controls the switcher via the front panel buttons or feet for tabletop operation. through remote contact closure or RS-232 controls. Rack and furniture mountability — The MMX 32 VGA A can be mounted on a rack shelf or under a desk or podium. Extron Power —...
Introduction MMX 32 VGA A Chapter Two Installation and Operation Mounting the MMX 32 VGA A Rear Panel Features and Cabling Front Panel Features and Operation MMX 32 VGA A • Introduction...
Mounting the MMX 32 VGA A Use 2 mounting holes on opposite corners. The MMX 32 VGA A can be set on a table, mounted on a rack shelf, or mounted under a desk, podium, or tabletop. Tabletop use Four self-adhesive rubber feet are included with the switcher.
Attach the furniture mounting brackets to the switcher with the provided machine screws (figure 2-3). Figure 2-4 — MMX 32 VGA A rear panel features Inputs Video and audio inputs — Connect computer video sources to these female 15-pin HD connectors.
Architectural Adapter Plate (AAP or MAAP). See chapter 3, wires can be easily pulled out even if tightly fastened “Remote Control”, for more information. by the captive screws. MMX 32 VGA A • Installation and Operation MMX 32 VGA A • Installation and Operation...
The MMX 32 VGA A also features audio breakaway through the Extron Simple Instruction Set or the Extron Universal Switcher Figure 2-8 — Front panel features Control Program (see chapter 3, “Remote Control”, for details).
Installation and Operation, cont’d MMX 32 VGA A Chapter Three Remote Control RS-232 Control Contact Closure Control 2-10 MMX 32 VGA A • Installation and Operation...
® -based control program. Switcher-initiated message The Remote connector on the MMX 32 VGA A is a female 9-pin D connector (figure 3-1). Pins not used for RS-232 control The following copyright message is initiated by the switcher are assigned to contact closure control as described later in this when it is first powered on.
= Mute 0 = no mute 1 = video mute 2 = audio mute 3 = video and audio mute ASCII to HEX Conversion Table Space MMX 32 VGA A • Remote Control MMX 32 VGA A • Remote Control...
1 stop bit, and “none” flow control. If you are performing this procedure to recover from corrupted firmware, the switcher responds only to the “n”, “q”, and “ upload” SIS commands. MMX 32 VGA A • Remote Control MMX 32 VGA A • Remote Control...
Page 16
Navigate to the folder where you saved the firmware copyright message: upgrade file. Select the file (figure 3-3). (C) Copyright 2003, Extron Electronics, MMX 32 VGA A, Ensure that the firmware upgrade is for the MMX Series Vx.xx switcher. Valid firmware files must have the file This message indicates that the firmware upload is extension “.s19”.
From within the Universal Switcher Control Program, press the F1 key. Contact Closure Control The MMX 32 VGA A can be controlled remotely using the optional Extron MMX 32 AAP contact closure control panel (part #70-277-01, -11, or -21) or the MMX 32 MAAP contact closure panel (part #70-277-12 or -22).
Input 2 pole — Connect this pole of the captive screw connector to pin 4 (output 1) or pin 8 (output 2) of the MMX 32 VGA A’s Remote connector. Input 3 pole — Connect this pole of the captive screw connector to pin 6 (output 1) or pin 9 (output 2) of the MMX 32 VGA A’s...
Remote Control, cont’d MMX 32 VGA A A ppendix A Specifications, Part Numbers, and Accessories Specifications Included Parts Optional Accessories 3-16 MMX 32 VGA A • Remote Control...
Input level ........TTL 2.5 V to 5.0 Vp-p, 4.0 Vp-p normal unbalanced at 1% THD+N Output level ........TTL: 4 V to 5 Vp-p, unterminated Input impedance ......510 ohms MMX 32 VGA A • Specifications, Parts, and Accessories MMX 32 VGA A • Specifications, Parts, and Accessories...
Included Parts Serial control port ......RS-232, 9-pin female D connector These items are included in each order for an MMX 32 VGA A: Baud rate and protocol ....9600 baud, 8 data bits, 1 stop bit, no parity Serial control pin configurations 2 = TX, 3 = RX, 5 = GND...