Trion FM 1000 Installation, Operation & Service Manual

Trion FM 1000 Installation, Operation & Service Manual

Electronic & media air cleaner

Advertisement

Quick Links

Model FM 1000
Electronic & Media Air Cleaner
Installation
Operation
Service
Please read these instructions carefully for
trouble free operation and to get the most out of
your
purchase.
For
further
information
concerning this project, contact your local Trion
representative
101 McNeill Road • Sanford, NC 27330
Phone: 800-884-0002 • Fax: 800-458-2379 • Email: sales@trioninc.com
www.trioninc.com
Manual Part No. 140627-001 • June 2002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FM 1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Trion FM 1000

  • Page 1 Trion representative 101 McNeill Road • Sanford, NC 27330 Phone: 800-884-0002 • Fax: 800-458-2379 • Email: sales@trioninc.com www.trioninc.com Manual Part No. 140627-001 • June 2002...
  • Page 2: Specifications

    The Red LED indicates High Voltage (approximately installation, operation and service of the FM 1000 E & M. 6800 VDC) is supplied to the Ionizer / Collector cell. Before installation and use of the air cleaner, carefully (Red not used on Media unit).
  • Page 3 Located the area to be cleaned or at the point 1. Unit model number Inside door recommended by your TRION Representative. 2. Unit serial number Inside door Remove a section of ceiling tile. 3. Part number and description Exploded views.
  • Page 4 Dirt build-up on the ionizing–collecting cell should not be indicating high voltage is being sent from the confused with dirt stains. Dirt stains are normal and power supply to the cell. (Not on FM 1000 should not affect efficiency. Media).
  • Page 5: Troubleshooting

    TROUBLESHOOTING PROBLEM SOLUTION 1. Check 120 VAC input power Unit does not operate 2. Broken lead in power cord Light not on 3. Bad speed controller 1. Broken wire between the speed controller Light on and the motor Blower does not run 2.
  • Page 7 FM 1000 E & M Unit Assembly Parts List Item Part Number Description 440549-001 Discharge grill (2 req.) 227833-006 Charcoal afterfilter (2 req.) 228276-001 Switch, 3 speed rotary 139999-001 Knob, switch 244223-001 Label, control switch ESP (not shown) 244224-001 Label, control switch Media (not shown)
  • Page 8 244225-004 Retainer (2 req.) 120456-001 Nylon Washer (2 req.) (not shown) 440541-001 Access door 422086-504 Ionizer/collector cell (electrostatic) 340553-001 Pleated media filter (Media) 140551-001 4 blade fan (electrostatic) 140552-001 5 blade fan (Media) 240537-001 Collector cell latch 340623-001 Motor 234458-006 High voltage contact board assy.
  • Page 12: Fm 1000E Wiring Diagram

    FM 1000E Wiring Diagram...
  • Page 14: Fm 1000M Wiring Diagram

    FM 1000M Wiring Diagram...
  • Page 15: Warranty

    WARRANTY All Trion air cleaners are warranted for component failure and workmanship for a period of three years after purchase. Do not return defective parts without prior permission from the factory. Contact your local Trion Distributor or Trion Customer Service Department at 1-800-884-002 of Fax 1-800-458-2379 to obtain material return authorizations and service information.