Troubleshooting; Section 15 Troubleshooting - Axis 540plus User Manual

Network print server
Hide thumbs Also See for 540plus:
Table of Contents

Advertisement

Troubleshooting

Section 15
Troubleshooting
LED Indicators
Indicator
Power
Network
Web Interface
Symptoms
The AXIS 540+/AXIS 560 Web in-
terface cannot be accessed from
a Web browser.
120
This section provides useful information to help you resolve difficulties
you might have with your AXIS 540+/AXIS 560. Fault symptoms,
possible causes and remedial actions are provided within a quick
reference table.
Please visit the Axis Web site for latest troubleshooting tips, more support
and additional help through the FAQ database or to fill in and submit a
Support question.
Color/Behavior
Green
Not lit
Orange
Orange flashing
Not lit
Possible causes
The AXIS 540+/AXIS 560 is not
connected properly.
Problem with your proxy server.
Other networking problems.
Explanation
OK
No power/Error
OK - network connected
Activity on network
No physical connection to the network
Remedial actions
1. Check Power and Network indicator.
2. Check that assignment of IP addresses
for the AXIS 540+/AXIS 560 is correct.
3. To further check the IP addresses, run
the Ping command from another com-
puter as described in "IP address check"
at the end of this chapter. Follow the
appropriate recommendations.
Verify the proxy server settings in your
Web browser.
1. Verify that your network is accessible
through your network socket.
2. Verify that your network cable is func-
tional.