II - SPECIFICATIONS
Safety devices
Remote control cable
Clearances from combustibles
- GENERAL
Appliance - AC 120 Volts - 60Hz. 15A - Dedicated
Remote control DC 12 Volts (Digital)
Flame failure - Flame rod
Boiling protection - 203°F
Remaining flame (OHS) 194°F bi-metal switch
Thermal fuse 264°F
Automatic frost protection - Bimetal sensor & anti-frost heaters
Combustion fan rpm check - Integrated circuit
Over current - Glass fuse (3 amp)
If remote fails or becomes disconnected unit defaults to
100°F with water flowing, this is an anti-scald feature.
Non-polarized two core cable or low voltage thermostat wire
Top of heater 6"
Front of heater 6"
Sides of heater 2"
Back of heater 0"
Floor 12"
Vent/Air Intake 0"
10
(12" min. recomended for service)
(24" min. recomended for service)