Sensor Maintenance - Scotsman FME504 Installation And User Manual

Fme504, fme804, nme454, nme654, series flake and nugget ice machine
Hide thumbs Also See for FME504:
Table of Contents

Advertisement

NME454, 654 & FME504, 804

SENSOR MAINTENANCE

1. The bin control is a device that senses light,
therefore it must be kept clean so it can "see". At
least twice a year, remove the bin control sensors
from the base of the ice chute, and wipe the inside
clean, as illustrated.
ICE LEVEL SENSORS
SLIDE TO REMOVE
CLEAN THE
LIGHT SENSORS
2. The ice machine senses water level by a probe
located in the water reservoir. At least twice a year,
the probe should be removed from the reservoir,
and the tip wiped clean of mineral build-up.
January 2007
Page 10
Clean the Probe's Tip with ice
machine cleaner and a clean,
soft cloth.