Operation/Care Of Your Appliance - Lennox Hearth Products Merit LMBV-42RMN Care And Operation Instructions Manual

Merit series b-vent gas fireplaces 42" lmbv models
Table of Contents

Advertisement

LENNOX MERIT
Do not use these appliances if any part has
been under water. Immediately call a qualified,
professional service technician to inspect the
appliance and to replace any parts of the control
system and any gas control which have been
under water.
Ne pas se servir de cet appareil s'il a été
plongé dans l'eau, complètement ou en partie.
Appeler un technicien qualifié pour inspecter
l'appareil et remplacer toute partie du système
de contrôle et toute commande qui ont été
plongés dans l'leau.
Test gage connections are provided on the front
of the millivolt gas control valve (identified E
for the inlet and A for the manifold side. (See
Figure 2 ). A 1/8" NPT test gage connection
is provided at the inlet and manifold side of
the electronic gas control valve (See Figure 3 ).
Minimum inlet gas pressure to the appliance is
4.5 inches water column (1.24 kPa) for natural
gas and 11 inches water column (2.74 kPa) for
propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to the ap-
pliance is 10.5 inches water column (2.62 kPa)
for natural gas and 13.0 inches water column
(3.23 kPa) for propane.
The appliance must be isolated from the gas
supply piping system (by closing its individual
manual shut-off valve) during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig
(3.5 kPa).
The appliance and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at pressures in excess of 1/2 psig
(3.5 kPa).
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
WARNING: FAIlURE TO COmPly WITH
THE INSTAllATION AND OPERATING
INSTRUCTIONS PROvIDED IN THIS
DOCUmENT WIll RESUlT IN AN Im-
PROPERly INSTAllED AND OPERATING
APPlIANCE, vOIDING ITS WARRANTy.
ANy CHANGE TO THIS APPlIANCE
AND/OR ITS OPERATING CONTROlS
IS DANGEROUS. ImPROPER INSTAl-
lATION OR USE OF THIS APPlIANCE
CAN CAUSE SERIOUS INjURy OR DEATH
FORm FIRE, bURNS, ExPlOSION OR
CARbON mONOxIDE POISONING.
SERIES B-VENT GAS FIREPLACES • 42" LMBV MODELS • CARE AND OPERATION INSTRUCTIONS
®
Carbon monoxide Poisoning: Early signs
of carbon monoxide poisoning are similar
to the flu with headaches, dizziness and/or
nausea. If you have these signs, obtain fresh
air immediately. Turn off the gas supply to the
appliance and have it serviced by a qualified
professional, as it may not be operating
correctly.
WARNING: b-vENT APPlIANCES ARE
NOT DESIGNED TO OPERATE IN NEGA-
TIvEly PRESSURED ENvIRONmENTS
(PRESSURE WITHIN THE HOmE IS
lESS THAN PRESSURES OUTSIDE).
SIGNIFICANT NEGATIvEly PRESSURED
ENvIRONmENTS CAUSED by WEATHER,
HOmE DESIGN, OR OTHER DEvICES
mAy ImPACT THE OPERATION OF
THESE APPlIANCES. NEGATIvE PRES-
SURES mAy RESUlT IN POOR FlAmE
APPEARANCE, SOOTING, DAmAGE TO
PROPERTy AND/OR SEvERE PERSONAl
INjURy. DO NOT OPERATE THESE AP-
PlIANCES IN NEGATIvEly PRESSURED
ENvIRONmENTS.
WARNING: CHIlDREN AND ADUlTS
SHOUlD bE AlERTED TO THE HAzARDS
OF HIGH SURFACE TEmPERATURES.
USE CAUTION AROUND THE APPlI-
ANCE TO AvOID bURNS OR ClOTHING
IGNITION. yOUNG CHIlDREN SHOUlD
bE CAREFUlly SUPERvISED WHEN
THEy ARE IN THE SAmE ROOm AS THE
APPlIANCE.
WARNING: DO NOT PlACE ClOTHING
OR OTHER FlAmmAblE mATERIAlS ON
OR NEAR THIS APPlIANCE.
AvERTISSEmENT: SURvEIllER lES
ENFANTS. GARDER lES vêTEmENTS,
lES mEUblES, l'ESSENCE OU AUTRES
lIqUIDES à vAPEUR INFlAmmAblES
lOIN DE l'APPAREIl.
OPERATION AND CARE OF yOUR
APPlIANCE
1. Appliance operation may be controlled
through a remotely located optional wall switch.
Separate switches may provide independent
control for the remote controlled fireplace
operation (optional equipment).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
In lieu of remote or remote wall switch opera-
tion, the appliance must be operated directly
through the controls located on the front of the
valve located within the control compartment
under the removable refractory access panel,
Figure 1.
Gas Controls
on Valve
Refractory
Access Panel
SIT Valve Shown
Figure 1
Operation of millivolt and electronic gas
control systems are different. Before lighting
and operating your appliance determine if you
have a millivolt or electronic appliance. Refer
to Figure 1 to access the gas control compart-
ment below the lower refractory panel. Millivolt
appliances will be fitted with one of the two gas
control valves shown in Figure 2. Appliances
with electronic systems will be fitted with the
electronic valve shown in Figure 3. Familiarize
yourself with the differing controls for the valve
your appliance uses.
To light millivolt appliances refer to the detailed
lighting instructions found in both English and
French on pages 10 and 11 of these instruc-
tions respectively. millivolt and electronic
appliance lighting instructions may also be
found on the pull out labels attached to the gas
control valve located within the gas control
compartment. Refer to Figure 2 to locate the
appropriate location for the spark ignitor used
with your appliance.
If your appliance is equipped with an optional
remote wall switch or remote control kit the
appliance main burner may be turned on and
off with the wall switch or remote control. If the
appliance is not equipped with a wall or remote
control, the main burner must be turned off and
on with the gas control knob. Turn the knob
counter-clockwise from the PILOT position to
ON to light the main burner, and clockwise from
ON to PILOT to turn off the main burner.
Piezo
Ignitor
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Merit lmbv-42renMerit lmbv-42rmp

Table of Contents