Checking Manifold pressure
MILLIVOLT VALVES
Natrual gas will have a manifold pressure of approximately 3.5"
w.c. for maximum input or 1.7" w.c. for minimum input at the
pressure regulator outlet with the inlet pressure to the pressure
regulator from a minimum of 4.5" w.c. for the purpose of input
adjustment to a maximum of 10.5" w.c.
propane gas will have a manifold pressure approximately 10.0"w.c.
(2.49kPa) for maximum input or 4.9"w.c. for minimum input at
the pressure regulator outlet with the inlet pressure to the pressure
regulator from a minimum of 11.0"w.c. for the purpose of input
adjustment to a maximum of 13.0"w.c.
HyDRAULIC THERMOSTAT VALVES
Natural gas will have a manifold pressure of approximately 6.0"
w.c. at the pressure regulator outlet with the inlet pressure to the
MINIMUM CLEARANCE TO PERPENDICULAR
COMBUSTIBLE SIDE-WALL
(FROM EDGE OF FRONT FRAME ASSEMBLY)
Page 14
GAS SUPPLY (continued)

CLEARANCES

8"
Figure 9
pressure regulator from a minimum of 7.0" w.c. for the purpose of
input adjustment to a maximum of 10.5" w.c.
propane gas will have a manifold pressure approximately 10.0"w.c.
at the pressure regulator outlet with the inlet pressure to the pressure
regulator from a minimum of 11.0"w.c. for the purpose of input
adjustment to a maximum of 13.0"w.c.
A test gage connection is located downstream of the gas appliance
pressure regulator for measuring gas pressure. The connection is a
1/8 inch N.P.T. plugged tapping.
Millivolt Control Valve
The valve regulator controls the burner pressure which should be
checked at the pressure test point. Turn captured screw counter
clockwise 2 or 3 turns and then place tubing to pressure gauge over
test point (Use test point "A" closest to control knob). After taking
pressure reading, be sure and turn captured screw clockwise firmly
to re-seal. Do not over torque. Check for gas leaks.
Combustible Material
No greeting cards, stockings or ornamentation of any type should
be placed on or attached to the fireplace. The flow of heat can
ignite combustibles.
12"
10"
COMBUSTIBLE
MANTEL/TRIM
AREA
1 3/4"
11"
Figure 10
26497-1-0310
23"