E V E R Y D A Y H O T T U B S
SPA CONTROL OPERATION
All models

START-UP

1. At initial power up, the LCD display on the panel will flash "LINK". Press any
on the buttons on the control panel to link the panel to the control box and
remove the "LINK" message from the display.
2. "RUN PMPS PURG AIR -- -- -- --" will be displayed on the panel. This is an
opportunity to run the pumps and purge any air from the system and
associated plumbing lines. This period will last 4-5 minutes or can be exited
by pressing the Temp +/- button.
3. "SET TIME" will be displayed on the panel window. To enter the time, press
the listed buttons in the following sequence. Button presses must occur
within 3-5 seconds of each other.
a. Temp +/-
b. Light: Press until you see "TIME" displayed in the LCD display on the
c. Temp +/- To display clock
d. Temp +/- To adjust hour (note the AM – PM indicator in the display)
e. Light: To move to minutes
f.
Temp +/- To adjust minutes
g. Light: To hold and exit or wait 10 seconds for automatic exiting
Note: In the event of a power interruption/loss, the start-up sequence
will need to be repeated.
OPERATING THE SPA
Jets 1
Press Jets 1 button to turn on pump one to low speed. Pressing a second time
will turn the pump on to high speed. Pressing a third time will turn the pump off.
The high speed of pump 1 will run for 15 minutes and then switch to low speed.
Once on low speed, the pump will run for 15 minutes and then shut off. The
high and low speed operation will stop after 15 minutes of use. If the system is
in a filter cycle or calling for heat, low speed will continue to run. To restart the
pump, press the Jets 1 button." The yellow LED indictor under the LCD display
will illuminate anytime the pump is running.
Jets 2 (Two Pump Models Only)
Press Jets 2 button to turn on pump two high speed. Pressing a second time will
turn the pump off. The high speed of pump 2 will run for 15 minutes and then
turn off. To restart the pump, press the Jets 2 button.
Adjusting temperature (factory default 38° C)
To adjust the temperature of the water, press the Temp +/ – button. The display
always shows actual water temperature. The first press of the button will display
the set temperature and begin to flash. Continue to press or hold the Temp +/ –
to reach the desired set temperature. Once the display stops blinking the new
temperature setting will be set. The factory default setting is 38° C. The
minimum temperature that can be set is 27° C and the maximum temperature
that can be set is 40° C. If a lower set temperature is desired, see User
Programming section – Dual Temperature Range.
®
O W N E R ' S
Soak
Pressing the Soak button will turn off all pump operation. This is a useful feature
when soaking in the hot water with no jets running is desired. The Soak feature
will last 60 minutes and then resume normal operation. Pressing any jet button
will override the soak feature and turn on the pumps or you can simply press the
Soak button to exit the mode. Turning the LED lights on and off will not affect
the quite soak mode. The yellow LED indictor light under the LCD display will
illuminate anytime this feature is engaged.
Note: If the system is heating it will take a few moments for the Quiet Soak
feature to engage.
Timer
Press the Timer button to start the timer. The display will start at E00 and begin
timing how long you have been in the spa or using a certain feature. "E" is for
elapsed and the two trailing characters track time in one minute intervals. The
display will alternate with the current water temperature every 10 seconds. The
timer will continue to run up to 60 minutes. To turn off, press the Timer button
one time. The yellow LED indictor below the LCD display will illuminate anytime
this feature is running.
Light
Press the Light button to turn the interior spa lights on and off. Pressing the
button repeatedly (within 2-3 seconds of each press) will allow for color scrolling
of the LED lights. If left on the lights will run for 60 minutes and then turn off
automatically.
USER PROGRAMMING
The following features allow for additional control and setting of the on-board
electronics. In most cases the factory default settings are adequate for normal
use and operation. To access any of the following features press Temp +/- and
then Light: then scroll through the features by continuing to press the Light
button.
You exit the programming mode at any time by continuing to press the Light
button until you arrive back at the temperature display or by simply pausing for
10 to 20 seconds.
Dual Temperature Range (Factory default "Range
The system supports the choice of two temperature ranges for controlling heat.
This feature can be useful if you plan on being gone for an extended period of
time or anticipate infrequent use of the spa. The temperature range indicator is
located on the bottom half of the LCD display and will be shown as "Range
for high range or "Range
" for low range. The default temperature range, or
high range, is 27° C to 40° C. The optional low range is 13° C to 27° C. To
change the range setting, press the listed buttons in the following sequence.
Button presses must occur within 3-5 seconds of each other.
1. Temp +/-
2. Light – until "TEMP" is displayed in the LCD window
3. Temp +/- to change range setting to
4. Light – to select and exit. To return the display to the original position, follow
the same sequence.
Mode (Ready mode is factory default - recommended)
This feature can be used for periods of when you are planning on being gone
for an extended amount of time and don't want the spa running more regularly.
Putting the unit in "Ready" mode will ensure the spa is at full temperature and
ready for use at any time. Putting the unit in "Rest" mode will only allow the spa
to heat during a scheduled filtration cycle. To access and change the mode,
press the listed buttons in the following sequence. Button presses must occur
within 3-5 seconds of each other.
M A N U A L
panel.
" recommended)
"
for high or
for low.