BATTERIES
3. Secure the battery cable(s)/ring terminal(s) to the battery terminal(s)/post(s),
BLACK to NEGATIVE (-) and RED to POSITIVE (+), with the provided 1/4-20
x 7/8-inch hex flange screw and hex flange locknut. Securely tighten.
4. Verify all battery cable(s)/ring terminal(s) are correctly installed and securely
tightened.
5. Slide terminal cap(s) down battery cable(s) and onto battery clamps.
6. Secure each terminal cap in place with a tie-wrap (Use tie-wraps 11-1/2-inches long).
NOTE: It will be necessary to trim excess tie-wrap in order to install the battery box top(s).
7. Install the battery with lid into the wheelchair. Refer to INSTALLING/REMOVING
BATTERIES in this SECTION.
NOTE: New Battery(ies) MUST be fully charged BEFORE using, otherwise the life of the battery(ies)
will be reduced.
8. If necessary, charge the battery(ies). Refer to CHARGING BATTERIES in this
SECTION.
POSITIVE (+) Battery
Terminal/Post
POSITIVE (+) Red
Battery Cable
1/4-20 Hex
Flange
Locknut
Group 22NF
NEGATIVE (-) Black
Battery
Battery
Cable
NEGATIVE (-) Battery
Terminal/Post
FIGURE 6 - CONNECTING BATTERY CABLES - DIRECT MOUNT
Part No. 1106627
1/4-20 x 7/8-Inch
Hex Flange Screw
CONNECT BATTERY
CABLE TO BATTERY
TERMINAL AS SHOWN.
METHOD
49
NEGATIVE (-)
RED
Battery
Battery
Terminal/
Tie-
Terminal
Post
Wrap
Cap
22 NF Battery
SECTION 8
POSITIVE (+)
Battery
Terminal/
Post
Tie-
Wrap
BLACK Battery
Terminal Cap
Xterra™GT™

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents