Troubleshooting - Thermador T30IF Series Use & Care Manual

Built-in freezers
Hide thumbs Also See for T30IF Series:
Table of Contents

Advertisement

Troubleshooting

Freezer
Fault
Appliance has no cooling capacity.
The interior light does not function.
The display does not come on.
The refrigerating unit switches on
g
g
more and more frequently and for
f
longer.
The temperature in the freezer
compartment is too cold.
The interior light does not function.
The appliance is giving off odors.
IceMaker
Fault
Ice maker does not appear to be
running.
g
Small ice cubes over a prolonged
p
period.
Possible cause
Power failure; the fuse has actuated;
the plug has not been inserted in the
electrical outlet properly.
Appliance door opened frequently.
f
Large quantities of fresh food placed in
the appliance.
The ventilation openings are covered.
Temperature has been set too low.
The bulb is defective.
The light switch is sticking.
Strong smelling foods have not been
packed in airtight containers.
Possible cause
The ice maker is not connected to the
power supply.
The ice maker has no water supply.
The freezer compartment temperature
is too high.
Other domestic appliances which use
water are in operation.
Water filter must be changed.
Wrong water pressure.
A wrong water valve has been
installed.
Remedial action
Check that the power is on.
The fuse must be switched on.
Check the plug.
Do not open the door unnecessarily.
Switch on Super function.
Remove obstacles and dirt.
Set a warmer temperature (see Setting the
temperature").
Change the bulb (see Changing the bulb").
Check whether it can be moved.
Clean the appliance. Pack strong smelling foods in
airtight containers (see Odors").
Remedial action
Call customer service.
Ensure that the water supply line is connected properly.
Check temperature of the freezer compartment. If
required, lower the temperature.
Avoid using e.g. a dishwasher, washing machine or
shower at the same time.
Instructions for changing the water filter can be found in
the enclosed installation instructions.
Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72 8.25 bar).
Self tapping valves and 3/16 inch (4.76 mm) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.