Important - Lennox Elite XP14−018−230 Installation Instructions Manual

Elite xp14 series
Hide thumbs Also See for Elite XP14−018−230:
Table of Contents

Advertisement

To Access Service Port:
A service port cap protects the service port core from
contamination and serves as the primary leak seal.
1. Remove service port cap with an appropriately sized
wrench.
2. Connect gauge set to service port.
3. When testing is completed, replace service port cap and
tighten as follows:
S
With torque wrench: Finger tighten and torque cap per
table 1.
S
Without torque wrench: Finger tighten and use an
appropriately sized wrench to turn an additional 1/6
turn clockwise.
11 12
10
9
8
7
Reinstall Stem Cap:
Stem cap protects the valve stem from damage and serves
as the primary seal. Replace the stem cap and tighten as
follows:
1
1/6 TURN
2
3
4
5
6
S
With
Torque
tighten and then torque cap per table 1.
S
Without Torque Wrench: Finger tighten
and use an appropriately sized wrench to turn an
additional 1/12 turn clockwise.
Only use Allen wrenches of sufficient hardness (50Rc −
Rockwell Harness Scale minimum). Fully insert the
wrench into the valve stem recess.
Service valve stems are factory−torqued (from 9 ft−lbs for
small valves, to 25 ft−lbs for large valves) to prevent
refrigerant loss during shipping and handling. Using an
Allen wrench rated at less than 50Rc risks rounding or
breaking off the wrench, or stripping the valve stem
recess.
See the Lennox Service and Application Notes
Corp.0807−L5
information.
Page 5
Wrench:
Finger
1/12 TURN
11 12
1
2
10
9
3
4
8
5
7
6

IMPORTANT

(C−08−1)
for
further
details
and
XP14 SERIES

Advertisement

Table of Contents
loading