    HT-7120 Troubleshooting This Troubleshooting Guide walks you step-by-step through the diagnosis of HT-7120 customer problems. It is important to follow these steps carefully, to ensure that the problem is diagnosed correctly, and therefore the appropriate repair action is taken. Getting Started 1.
  • Page 4 Replace the chair. DEALER NOTE: You may wish to replace the air pump instead of replacing the chair. Replace the chair. My chair won’t swivel or the pedestal is broken. "Convenience Outlet" on page My convenience outlet doesn’t work. HT-7120 Troubleshooting Guide...
  • Page 5 4. Reinsert the fuse holder into the power panel, then turn it 1/8 turn clockwise to secure it. 5. Plug the chair back into the wall outlet and turn it on. 6. Verify that the chair is now receiving power. HT-7120 Troubleshooting Guide...
  • Page 6 2. Watch the remote control timer until it counts down at least five minutes. 3. Check the left and right sides of the backrest to determine if either side feels warm. 4. If either side does not feel warm, replace the backrest. HT-7120 Troubleshooting Guide...
  • Page 7: Convenience Outlet

    3. Turn the power switch to OFF and unplug the chair from the wall outlet. 4. Using a small screwdriver or a coin, turn the fuse holder (located on the power panel) approximately 1/8 turn counter-clockwise. The fuse holder pops out. HT-7120 Troubleshooting Guide...
  • Page 8 6. Reinsert the fuse holder into the power panel, then turn it 1/8 turn clockwise to secure it. 7. Plug the chair back into the wall outlet and turn it on. 8. If the convenience outlet is still not receiving power, replace the backrest cover. HT-7120 Troubleshooting Guide...