Sending Messages to a Pager
The FOCUS CADET system can transmit messages to up to 8 paging
services (typically at least one for each group). The types of messages are
divided into 4 categories: System Troubles, Point Troubles, Alarms and
Open/Closes.
The format of the pager message is as follows:
EEE GGG UUUU
EEE = Event Code
GGG = Group Number (001-008)
UUUU = User Number (for open/closes) or Point Number.
The possible event codes are:
111 = Fire Alarm
222 = Hold-up or Hostage Alarm
333 = Burglary Alarm
400 = Group failed to Turn OFF
444 = Group was Turned OFF
The following is an example of a pager message:
444 001 0025 − Group 1 was turned OFF by user 25.
System Operation (cont'd)
500 = Group Failed to Turn ON
555 = Point or System Trouble
777 = Group was Turned ON
911 = Personal Emergency (Medical
Alarm)
– 71 –
Need help?
Do you have a question about the Focus Cadet and is the answer not in the manual?