INSTALLATION INSTRUCTIONS
SPACE FOR FIXING
The cooker can be close fitted below hotplate level. This requires a minimum
distance of 600mm between cupboard units of hotplate height.
When installing next to a tall cupboard, partition or wall, for a minimum
distance of 400mm above hotplate level, allow a side clearance of at least
65mm.
The diagram below illustrates the minimum clearance between the cooker
and adjacent walls, cupboards etc.
The wall behind the cooker between the hotplate and 450mm above, and the
width of the cooker, must be a non-combustible material such as ceramic wall
tiles.
COOKER HOODS
If a cooker hood is to be installed, refer to the cooker hood manufacturers'
instructions regarding fixing height.
UNPACKING THE COOKER
Unpack the components from inside the grill and oven: Check that the
following parts are present:
Grill pan and grid
Oven shelves (3)
Aluminium burner bodies (4)
600 mm Min
Pan Supports
Enamelled burner caps (4)
Literature
If the cooker is to be fitted close
to a corner base unit on the left
hand side, ensure that there is a
65 mm Min
clearance of at least 50mm to
allow the oven door to open
fully for when removing oven
shelves.