Harman Home Heating OAKLEAF Owner's Manual page 18

Non-catalytic, top load, wood burning room heater
Table of Contents

Advertisement

Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection)
Flue Liner with Re-
quired Air Space
Stainless Steel Chimney
Connector Must Extend
to Flue Liner
Minimum 8" Masonry
Thickness in Front of
Smoke Chamber
Use Damper Adapter or Seal with
Non-Combustible Material
Damper Plate is Removed
or Fastened in Open Posi-
tion
Listed Fireplace Trim
Protection for Re-
duced Clearance
Floor Protection*
Combustible Floor
*Floor Protection in Accordance with Solid Fuel Appliance Listing
The Chimney Connector shall Not Pass Through an Attic or Roof space, Closet
or similar Concealed space, a floor or Ceiling.
18
Dry Seasoned Wood Only!
NOTICE: When using rear flue configuration, a
new upper rear heat shield, #1-00-797066 must be
installed in place of the existing shield.
Oakleaf Woodburning stove
3-90-798
Airtight
insulated
Clean-Out
Save These Instructions