PleaSe read tHIS entIre Manual beFOre YOu InStall and uSe YOur neW rOOM Heater. FaIlure
tO FOllOW InStruCtIOnS MaY reSult In PrOPertY daMage, bOdIlY InjurY, Or even deatH.
FOr uSe In tHe u.S. and Canada. tHe OakWOOd IS nOt aPPrOved FOr MObIle HOMe InStallatIOn.
IF tHIS HarMan StOve IS nOt PrOPerlY InStalled, a HOuSe FIre MaY reSult. FOr YOur SaFetY, FOllOW
InStallatIOn dIreCtIOnS.
COntaCt lOCal buIldIng Or FIre OFFICIalS abOut reStrICtIOnS and InStallatIOn InSPeCtIOn
reQuIreMentS In YOur area.
COntaCt YOur lOCal autHOrItY (SuCH aS MunICIPal buIldIng dePartMent, FIre dePartMent, FIre
PreventIOn bureau, etC.) tO deterMIne tHe need FOr a PerMIt.
Cette guIde d'utIlISatIOn eSt dISPOnIble en FranCaIS. CHez vOtre COnCeSSIOnnaIre de HarMan
HOMe HeatIng.
Save tHeSe InStruCtIOnS.
#3-90-08327

Advertisement

Table of Contents
loading

Summary of Contents for Harman Home Heating Oakwood

  • Page 1: Safety Notice

    FOllOW InStruCtIOnS MaY reSult In PrOPertY daMage, bOdIlY InjurY, Or even deatH. FOr uSe In tHe u.S. and Canada. tHe OakWOOd IS nOt aPPrOved FOr MObIle HOMe InStallatIOn. IF tHIS HarMan StOve IS nOt PrOPerlY InStalled, a HOuSe FIre MaY reSult. FOr YOur SaFetY, FOllOW InStallatIOn dIreCtIOnS.
  • Page 3: Table Of Contents

    Please read this entire manual before you install and use your new heating appliance. Failure to follow instructions may result in property damage, bodily injury, or even death. Harman Home Heating 352 Mountain House Road Halifax, PA 17032 U.S.A. Harman Oakwood...
  • Page 4: Introduction

    Harman Air Wash System. The Harman Oakwood has an ash pan with its own ash door that is used to remove ashes while the stove is in operation. This means you can keep one fire all winter if you desire.
  • Page 5: Specifications

    26.235" 18.037" 21" 7.5" 30.234" 21" The Harman Oakwood meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold after July 1, 1990. Weight..........440 lbs Flue Size........6 inch Log Length Recommended...21" Max Heating Capacity......2,000 sq. ft. Average Emissions.......2.32 Grams Per Hr.
  • Page 6 SPeCIFICatIOnS Top Load Door Optional Cooking Grill Top Load Opening Bypass Damper Control Handle Front Load Door Grate Andirons Front Load Door Latch Air Control Ash Door Ash Door Latch Harman Oakwood...
  • Page 7 ONE DOOr OpEN at a tImE Do not burn garbage or flammable fluids such as gasoline, naptha, or engine oil. The glass used in your Oakwood is manufactured to exact standards to withstand the high heat of the fire, but like all glass, it must be treated with common sense and care. Never abuse the glass by slamming the door shut or striking the glass with a heavy object.
  • Page 8 Two important controls - the damper bypass handle and The Combustion Process the air control lever regulate the operation and output of the Combustion in the Harman Oakwood is precisely con- stove. trolled and is best explained in two parts. To open the top or front loading door, you must open During a wood fire, combustion air enters at the bottom the damper bypass, or smoke will come in the room.
  • Page 9 If, after five minutes of burning with the damper closed, smoke is visible coming from the chimney, you probably do not have the proper coal bed. Open the bypass damper and continue with the process until a significant coal bed is formed. Harman Oakwood 9...
  • Page 10: Operation/Building A Fire

    Overfiring is prematurely. caused by: 1. Too much air flowing through the stove The Oakwood was designed to provide access to the too quickly. 2. You may have positioned the primary ash pan without the need for opening the main door.
  • Page 11: Installation

    For parallel installations, the required clearance dis- tances from the stove are: (see next pages for more details, The Oakwood must be installed on a non-combustible including the use of double walled pipe and optional heat floor or a non-combustible floor protector. Floor protection,...
  • Page 12 InStallatIOn/ClearanCeS 21" 25" Harman Oakwood See NFPA 211 for more installation clearance reductions when using USM wall protection, etc.
  • Page 13 InStallatIOn/ClearanCeS See NFPA 211 for more installation clearance reductions when using USM wall protection, etc. Harman Oakwood...
  • Page 14 InStallatIOn/ClearanCeS Harman Oakwood See NFPA 211 for more installation clearance reductions when using USM wall protection, etc.
  • Page 15 If the fireplace floor can hold the 500 lb. (250 kg) The Oakwood should not be installed into a factory Oakwood, the stove should only be placed into the fire- built fireplace unless the hearth area is designed to place opening to the point that operation of the damper take the maximum weight of the stove.
  • Page 16: Venting

    When installed and operated according to this manual, of CAN/CSA B365, the national standard. the Oakwood will produce enough hot gases to keep United States In the U.S., the national code is NFPA the chimney warm so that adequate draft is maintained 211.
  • Page 17: The Chimney

    103, or (2) a code-approved masonry chimney with a tile Canada certain exceptions may be made. Be sure to flue liner. In Canada, the Oakwood is listed for use with contact your building code inspection official to see if prefabricated chimneys tested and listed to the high tem-...
  • Page 18 All prefabricated chimneys must Oakwood. In addition to the requirements found in the be tested to either the U.S. or Canadian high-temperature previous paragraphs, it is important to be aware that all standards, UL 103 or ULC-629.
  • Page 19 Other causes of poor ventilation or draft are icing, exhaust fans, a blocked outside air inlet, and room air starvation. If your stove is sluggish and you get occa- sional odor, check these possibilities and increase the air flow in your home. Harman Oakwood...
  • Page 20 Collar Chimney Sections Chimney Cap Roof Flashing roof radiation roof Factory-Built shield radiation metal Chimney shield attic sealed storm Collar radiation Roof Flashing shield Cathedral style Chimney support minimum air space Chimney with Chimney Listing support Finishing Col- Chimney Con- nector Chimney Connector Harman Oakwood...
  • Page 21 Flue liner with re- quired air space Three Sheet Metal Screws airtight per Joint of Chimney insulated Connector Clean-out mantel and trim pro- tection Damper Closed and sealed with Non-Combus- Floor protection* tible Material. Combustible Floor * Floor protection in accordance with Solid Fuel Appliance Listing Harman Oakwood...
  • Page 22 Oakwood to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection) Flue liner with re- airtight quired air space insulated Clean-Out Stainless Steel Chimney Connector Must Extend to Flue liner Minimum 8" Masonry Thickness in Front of smoke Chamber Use Damper Adapter or Seal with Non-Combustible Material Damper Plate is Removed or Fastened in Open Posi- tion Listed Fireplace Trim protection for re- duced Clearance Floor protection* Combustible Floor *Floor Protection in Accordance with Solid Fuel Appliance Listing Harman Oakwood...
  • Page 23 Full Relining Fireplace Conversion: Freestanding Appliance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner manufacturer's instructions on insulation and support UL1777 Insulated Stainless Steel Flex liner or Other approved lin- ing System in Offsets. Listed Fireplace Trim Protection for reduced Clearance Damper Plate Removed or Fas- tened in Open Position Use Damper Adapter or Seal with Non-Combus- tible material Floor protection* Combustible Floor *Floor Protection in Accordance with Solid Fuel Appliance Listing Harman Oakwood...
  • Page 24 Flue liner with required air space Listed or Approved Thimble Assembly Combustible 1" Clearance for Complex- Wall ity Exterior Chimney 2" Clearance for Interior sheetrock airtight Chimney and 2" Clear- insulated ance for NFPA 211-Type Clean-out Approved Thimbles mantel & trim protection Damper Closed and sealed with Non- Combustible Material. Floor protection* Combustible Floor * Floor Protection in Accordance with Solid Fuel Appliance Listing ** Check with your local building codes for clearance. Harman Oakwood...
  • Page 25: Maintenance

    Some users have dam- it on a soft surface, or door stand that is an optional feature aged their combustion package with vacuum cleaner tools, with the Oakwood. and fire pokers. Carefully remove damaged glass, gasket material, and hold down clips (set aside).
  • Page 26 To change a gasket, first remove the worn The FireDome on the Oakwood cuts creosote to almost fiberglass and clean the area with a wire brush. Also clean nothing when properly burned with dry seasoned wood.
  • Page 27: Options

    An outside air duct less than 5' (1525 mm) long may Bottom Heat shield be 3" [80mm] in diameter, and be made of masonry tile, The bottom heat shield allows the Oakwood to be in- 26 gauge (0.019)galvanized steel, or other approved stalled on a combustible floor using any non-combustible noncombustible material;...
  • Page 28: Service Parts

    Oakwood Service Parts beginning Manufacturing date: n/a Cast Iron Stove ending Manufacturing date: active 1-90-02490-1 (black), 1-90-02490-2 (Charcoal), 1-90-02490-3 (goldenfi re), 1-90-02490-4 (Metallic blue), 1-90-02490-5 (Honey glo), 1-90-02490-10 (Mojave red), 1-90-02490-12 (Forest green) Part number list on following page. 10/10...
  • Page 29 Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 30 Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 31 Oakwood Service Parts beginning Manufacturing date: n/a ending Manufacturing date: active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 32 Harman Oakwood...
  • Page 33 Harman Oakwood...
  • Page 34 Harman Oakwood...
  • Page 36 Proudly Printed On 100% Recycled Paper...

Table of Contents