Harman Home Heating OAKLEAF Owner's Manual

Non-catalytic, top load, wood burning room heater

Advertisement

Quick Links

Owner's Manual
Installation and Operation
Model:
Oakleaf
Non-Catalytic, Top Load,
Wood Burning Room Heater
Item #1-90-797000
Important operating and
maintenance instructions
included.
PLEAsE REAd THIs ENTIRE MANuAL
BEfORE INsTALLATION ANd usE Of
THIs WOOd-BuRNING ROOM HEATER.
fAILuRE TO fOLLOW THEsE INsTRuC-
TIONs COuLd REsuLT IN PROPERTy
dAMAGE, BOdILy INjuRy OR EvEN
dEATH.
dO NOT sTORE OR usE GAsOLINE OR
OTHER fLAMMABLE vAPORs ANd LIquIds
IN THE vICINITy Of THIs OR ANy OTHER
APPLIANCE.
• dO NOT OvERfIRE - If ANy ExTERNAL PART
sTARTs TO GLOW, yOu ARE OvERfIRING.
CLOsE AIR CONTROLs. OvERfIRING WILL
vOId yOuR WARRANTy.
• COMPLy WITH ALL MINIMuM CLEARANCEs
TO COMBusTIBLEs As sPECIfIEd. fAILuRE
TO COMPLy MAy CAusE A HOusE fIRE.
CAuTION
TEsTEd ANd APPROvEd fOR usE WITH dRy,
sEAsONEd CORdWOOd ONLy. dO NOT BuRN
WET OR GREEN WOOd. BuRNING ANy OTHER
TyPE Of fuEL WILL vOId yOuR WARRANTy.
www.harmanstoves.com
NOTICE
dO NOT dIsCARd THIs MANuAL
Read, understand and
follow these instructions
for safe installation and
operation.
WARNING
3-90-798
Leave this manual with
party responsible for use
and operation.
WARNING
HOT suRfACEs!
GLAss ANd OTHER suRfACEs
ARE HOT duRING OPERATION
ANd COOL dOWN.
HOT, WILL CAusE BuRNs.
dO NOT TOuCH GLAss uNTIL IT Is COOLEd
NEvER ALLOW CHILdREN TO TOuCH GLAss
kEEP CHILdREN AWAy
CAREfuLLy suPERvIsE CHILdREN IN sAME
ROOM As fIREPLACE.
ALERT CHILdREN ANd AduLTs TO HAzARds Of
HIGH TEMPERATuREs.
HIGH TEMPERATuREs MAy IGNITE CLOTHING OR
OTHER fLAMMABLE MATERIALs.
kEEP CLOTHING, fuRNITuRE, dRAPERIEs ANd
OTHER fLAMMABLE MATERIALs AWAy.
CAuTION
CHECk BuILdING COdEs PRIOR TO INsTALLATION.
INsTALLATION MusT COMPLy WITH LOCAL, REGIONAL,
sTATE ANd NATIONAL COdEs ANd REGuLATIONs.
CONsuLT LOCAL BuILdING, fIRE OffICIALs OR AuTHOR-
ITIEs HAvING juRIsdICTION ABOuT REsTRICTIONs,
INsTALLATION INsPECTION, ANd PERMITs.
Rev: 3
May, 2011

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OAKLEAF and is the answer not in the manual?

Questions and answers

Summary of Contents for Harman Home Heating OAKLEAF

  • Page 1 Owner's Manual Installation and Operation Model: Oakleaf Non-Catalytic, Top Load, Wood Burning Room Heater Item #1-90-797000 NOTICE dO NOT dIsCARd THIs MANuAL • • • Important operating and Read, understand and Leave this manual with maintenance instructions follow these instructions party responsible for use included.
  • Page 2 The Oakleaf has huge features in an elegantly small package. With a heating capacity of 1400 to 1600 ft², The Oakleaf takes advantage of Harman’s 30+ years of stove design, technology and manufacturing. The Firedome secondary combustion system provides for super-clean burning and minimal maintenance.
  • Page 3: Table Of Contents

    Oakleaf Woodburning stove TABLE Of CONTENTs section 1: Listing and Code Approvals section 9: service & Maintenance A. Soot Formation (Removal)....28 A. Appliance Certifications......4 B. Mobile Home Approval.......4 B. General Maintenance Procedures ..29 C. Glass Specifications......4 D. Electrical Rating ........4 section 10: Reference Materials E.
  • Page 4: Section 1: Listing And Code Approvals

    Oakleaf Woodburning stove Listing and Code Approvals E. BTu & Efficiency specifications A. Appliance Certification Model: Oakleaf Woodburning Stove Particulate Emissions 2.2g/hr Avg Laboratory: OMNI-Test Laboratories, Inc. Rating: Report No. 135-S-26-6.2 15,000 - 39,000 / hr *BTU Input: Type: Solid Fuel Room Heater / Wood Heating Capacity: 1,400-1,600 sq.
  • Page 5: Section 2: Special Warnings And Notes

    CO fumes are toxic and can be fatal. stove such as car or lawn mower exhaust. The Oakleaf is a natural draft system which relies on a If the alarm sounds properly designed chimney to remove CO and other com- 1.
  • Page 6: Considerations

    Oakleaf Woodburning stove Getting started A. design, Installation & Location B. fire safety Considerations Maintain the designated clearances to combustibles. 1. Appliance Location Insulation must not touch the chimney. You must maintain the designated air space around the chim- Consideration must be given to safety, convenience, ney.
  • Page 7: Component Locator

    Latch d. flue direction Conversion The Oakleaf features an adjustable flue collar for rear or top exit. Follow these instructions for changing the direction. First, remove the upper rear heat shield by removing 8 tek screws that secure it. Reaching upward through the firebox and the open bypass damper, loosen the retainer bolts on each of the flue collar and the cast iron plate.
  • Page 8: Pre-Use Checklist

    Oakleaf Woodburning stove E. Pre- use Check List Place the appliance in a location near the WARNING final installation and follow the procedures INsPECT APPLIANCE ANd COMPONENTs below: fOR dAMAGE. dAMAGEd PARTs MAy Open the appliance and remove all articles IMPAIR sAfE OPERATION.
  • Page 9: Section 4: Dimensions & Clearances

    #1-00-797066 must be installed in place of the existing shield. 26.2" (665.5mm) Centered 27.6" (701mm) 25.6" The Harman Oakleaf meets (650mm) the U.S. Environmental Protec- 18.9" (480mm) tion Agency’s emission limits for wood heaters sold after July 1, 1990.
  • Page 10: Clearances To Combustibles

    Oakleaf Woodburning stove B. Clearances To Combustibles CLEARANCE TO COMBusTIBLEs: vertical venting Configuration Location Pipe clearance may be reduced using double wall unit to side Wall 17" / 432 mm or insulated connector pipe, provided that you unit to Back Wall 14"...
  • Page 11 Oakleaf Woodburning stove Pipe clearance may be reduced using double wall CLEARANCE TO COMBusTIBLEs: or insulated connector pipe, provided that you Corner Installation, vertical vent adhere to the specified clearances from the stove Location itself. follow pipe manufacturer's guidelines. shield Corner to Wall 14"...
  • Page 12: Floor Protection

    * Floor protection for the front and sides as mea- sured from the appliance door opening. floor Protection Requirements If the Oakleaf is being installed on a combustible floor, the bottom heat shield (part # 1-00-797058) must be installed along with proper floor protection material.
  • Page 13: Section 5: Chimneys And Venting

    When installed and operated according to this man- two other methods are described in detail in the current ual, the Oakleaf will produce enough hot gases to keep issue of CAN/CSA B365, the national standard. the chimney warm so that adequate draft is maintained United States In the U.S., the national code is NFPA...
  • Page 14: The Chimney

    Oakleaf Woodburning stove Non-combustible cover, one Closest side only. If two covers are Combustible Minimum 2" (50mm) used, each must be mounted Hole with a minimum Material Clearance to Brick on non-combustible spacers clearance of 18" (450 mm) at least 7/8" (21mm) away between connector and wall.
  • Page 15 Oakleaf Woodburning stove 1. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have it thoroughly inspected and cleaned. Any faults which make the chimney unsafe and unusable must be repaired prior to use. These can include improper height,...
  • Page 16: Factory Built Chimney

    Oakleaf Woodburning stove Standard Ceiling Installation with Cathedral Ceiling Installation with Factory Built Chimney Factory Built Chimney Chimney Cap Storm Collar Chimney Sections Chimney Cap Roof Flashing Roof Radiation Roof Factory-Built Shield Radiation Metal Chimney Shield Attic Sealed Storm Collar...
  • Page 17 Oakleaf Woodburning stove Chimney Breach Fireplace Conversion with Non-Combustible Wall Minimum Clearance to Unprotected Ceiling 16" Chimney Connector Sealed at Thimble Flue Liner with Re- quired Air Space Three Sheet Metal Screws Airtight per Joint of Chimney insulated Connector Clean-out...
  • Page 18 Oakleaf Woodburning stove Oakleaf to Flue Fireplace Conversion (Minimum NFPA 211 Liner Connection) Flue Liner with Re- Airtight quired Air Space insulated Clean-Out Stainless Steel Chimney Connector Must Extend to Flue Liner Minimum 8" Masonry Thickness in Front of Smoke Chamber...
  • Page 19 Oakleaf Woodburning stove Full Relining Fireplace Conversion: Freestanding Appliance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner manufacturer's instructions on insulation and support UL1777 Insulated Stainless Steel Flex Liner or Other Approved Lin- ing System in Offsets.
  • Page 20 Oakleaf Woodburning stove Chimney Breach Fireplace Conversion with Combustible Wall Minimum Clearance from Chimney Connector to Un- protected Ceiling 16"** Flue Liner with Required Air Space Listed or Approved Thimble Assembly Combustible 1" Clearance for Complex- Wall ity Exterior Chimney 2"...
  • Page 21: Mobile Home Installation

    Oakleaf Woodburning stove Mobile Home A. Mobile Home Installation CAuTION Mobile home approval - u.s. only. MAINTAIN sTRuCTuRAL INTEGRITy Of MOBILE dO NOT INsTALL IN A MOBILE HOME IN CANAdA. HOME: • fLOOR, WALL, CEILING ANd/OR ROOf. 1. An outside air inlet must be provided for combus-...
  • Page 22: Section 7: Appliance Set-Up

    6. Slide the other end of the metal intake flex pipe hooks (A). into the stub on the rear of the Oakleaf and secure When grilling, you'll want to keep the fire size small it with aluminum tape. This air intake will supply and the bypass damper in the open position.
  • Page 23: Optional Blower Kit

    Optional Bottom Heat shield Part #1-00-797058 must be purchased and installed whenever the Oakleaf is installed on a protected com- bustible floor. The shield installs on four bolts that are protruding downward from the base of the stove body.
  • Page 24: Section 8: Operating Instructions

    Your stove is not an incinerator - do not 1. draft burn garbage, painted or treated wood, plastic, or other Before you install and operate your Oakleaf debris. wood stove, please read the entire contents of this Keep the area around the stove free from clutter.
  • Page 25: Combustion Process

    Ash The glass used in your Oakleaf is manufactured to remains after the burning is complete. Within the primary exact standards to withstand the high heat of the fire,...
  • Page 26: User Controls

    Oakleaf Woodburning stove For low burn, slide the air control to the left. For d. user Controls medium burns, use notches 1 to 2. Maximum heat is Two important controls - the damper bypass handle attained with the air control all the way to the right. Do and the air control lever regulate the operation and not burn the stove continuously at the maximum setting.
  • Page 27: Save These Instructions

    If you notice signs of overfiring, reduce prematurely. the air supply to the fire, and review the Maintenance The Oakleaf is designed to provide access to the section in this manual. ash pan without the need for opening the main door.
  • Page 28: Section 9: Service & Maintenance

    Oakleaf Woodburning stove solid fuel burning spave heaters must be cleaned regularly, service & Maintenance as soot, ash and creosote may accumulate. Creosote- formation and Need for Removal; When wood is burned slowly, it produces tar and other seasonal cleaning...
  • Page 29: General Maintenance Procedures

    Oakleaf Woodburning stove 2. door Glass B. General Maintenance Procedures • frequency: As needed / Weekly • By: User 1. Ash Removal Whenever the view of the fire is obstructed, or weekly, • frequency: As needed / Every day or two clean the glass using a soft cloth dampened with stan- •...
  • Page 30 Oakleaf Woodburning stove 3. firebox 5. Chimney Connector • frequency: As necessary / Yearly • frequency: As necessary / Yearly • By: User • By: Qualified Service Technician / User Cleaning the firebox and internal heat exchange sur- At the end of the burn season, brush and clean all faces is recommended to maintain thermal efficiency.
  • Page 31: Section 10: Reference Materials

    Oakleaf Woodburning stove Reference Materials Save These Instructions 3-90-798 Dry Seasoned Wood Only!
  • Page 32: Service Parts Listing

    Oakleaf service Parts Beginning Manufacturing date: sept 2010 Cast Iron Wood stove Ending Manufacturing date: Active 1-90-797000-1 (Black), 1-90-797000-2 (Charcoal), 1-90-797000-3 (Goldenfi re) Part number list on following page. 03/11...
  • Page 33 Oak Top Load Door 3-00-249115P Gasket-3/8 Round LD 5 Ft 1-00-37525 Inside Plate-Left 1-10-797104 Gasket-1/4 Round PSA 15 Ft 1-00-2312 Oakleaf Package 3-40-797022 Gasket-1/4 Round PSA 15 FT 1-00-2312 Ramp Assembly 1-10-797109 Gasket-1/4 Round PSA 15 FT 1-00-2312 Brick Clip Set...
  • Page 34 Oakleaf service Parts Beginning Manufacturing date: sept 2010 Ending Manufacturing date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement stocked parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 35: Epa Hang Tag

    Manufactured by: HarMan HOMe HeatInG MOdel: Oakleaf u.S. envIrOMental PrOtectIOn aGency Meets EPA particulate matter (smoke) control requirements for noncatalytic wood heaters built on or after July 1, 1990. SMOke Grams Per Hour effIcIency 100% Wood heaters with higher efficiencies cost less to operate.
  • Page 36: Warranty Policy

    Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance...
  • Page 37 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. •...
  • Page 38 Oakleaf Woodburning stove service & Maintenance Log date Of service Performed By description Of service Dry Seasoned Wood Only! 3-90-798 Save These Instructions...
  • Page 40 Proudly Printed On 100% Recycled Paper...

Table of Contents