Installing Dimms - HP Compaq 8100 Elite Hardware Reference Manual

Convertible minitower business pc and convertible minitower workstation
Hide thumbs Also See for Compaq 8100 Elite:
Table of Contents

Advertisement

Installing DIMMs

CAUTION:
drain before adding or removing memory modules. Regardless of the power-on state, voltage is always
supplied to the memory modules as long as the computer is plugged into an active AC outlet. Adding
or removing memory modules while voltage is present may cause irreparable damage to the memory
modules or system board.
The memory module sockets have gold-plated metal contacts. When upgrading the memory, it is
important to use memory modules with gold-plated metal contacts to prevent corrosion and/or oxidation
resulting from having incompatible metals in contact with each other.
Static electricity can damage the electronic components of the computer or optional cards. Before
beginning these procedures, ensure that you are discharged of static electricity by briefly touching a
grounded metal object. For more information, refer to
When handling a memory module, be careful not to touch any of the contacts. Doing so may damage
the module.
1.
Remove/disengage any security devices that prohibit opening the computer.
2.
Remove all removable media, such as compact discs or USB flash drives, from the computer.
3.
Turn off the computer properly through the operating system, then turn off any external devices.
4.
Disconnect the power cord from the power outlet and disconnect any external devices.
CAUTION:
power to drain before adding or removing memory modules. Regardless of the power-on state,
voltage is always supplied to the memory modules as long as the computer is plugged into an
active AC outlet. Adding or removing memory modules while voltage is present may cause
irreparable damage to the memory modules or system board.
5.
Remove the access panel.
WARNING!
components to cool before touching.
6.
Locate the memory module on the system board.
NOTE:
load order instructions.
10
Hardware Upgrades
You must disconnect the power cord and wait approximately 30 seconds for the power to
You must disconnect the power cord and wait approximately 30 seconds for the
To reduce risk of personal injury from hot surfaces, allow the internal system
On the Z200 Workstation, see the service label on access panel for memory location and
Electrostatic Discharge on page
45.
ENWW

Hide quick links:

Advertisement

Table of Contents
loading