REMOTE AND INDOOR TEMPERATURE

The remote temperature information line is located right below the weather
forecast line of the main unit's display.
The wave icon is located above the remote channel number indicates the
reception status from the corresponding remote sensor.
There are three following types of the reception status may be displayed:
The unit is in a searching
mode.
Temperature reading is
securely registered.
No signals detected.
The indoor temperature with the icon IN is located below the remote
temperature information line.
NOTE: If the indoor or remote temperature goes above or below operating
range stated in specifications, the main unit's display ( weather) will show
dashes "- - -" on the corresponding line.

WEATHER FORECAST

This unit is capable of detecting the atmospheric pressure changes. Based on
collected weather data, it forecasts the weather for the next 12 to 24 hours.
When the
display
shows...
Forecast is...
Sunny
Partly
Cloudy
NOTE: The weather forecast accuracy is approximately 70%.
- - -
Cloudy
Rainy
Snowy
11
The main unit display shows forecasted (predicted) not current
conditions. The SUNNY icon indicates clear weather, even when
displayed during the night-time.

MAXIMUM AND MINIMUM READINGS

The maximum and minimum record of the indoor and remote temperature will
be automatically stored in the memory of the main unit (receiver).
To display the minimum, maximum or the current reading press MEM button.
If no button is pressed for the next 15 seconds, the unit will return to the current
temperature and humidity display.
To clear the memory, press and hold MEM button for two seconds and all
previously stored readings will be erased.

LOST COMMUNICATION

If the main unit display line for the remote sensor reading goes blank, press
and hold DOWN (▼) button for 2 seconds to begin a new signal search. If the
signal still isn't received, please make sure that:
• The remote sensor is in its proper location.
• The distance between main unit and remote sensor(s) is not over 328
feet (100 meters)
• The path between units is clear of obstacles. Shorten the distance if
necessary.
• Fresh batteries are installed correctly in both remote sensor and main
unit.
If there is no reception, please perform the following steps:
• Bring the main unit and remote sensor close together.