TOTALINE P374-1900 Owner's Manual page 42

7-day programmable digital thermostat humidity control
Hide thumbs Also See for P374-1900:
Table of Contents

Advertisement

Setting a Thermostat Output Jumper
Setting a Thermostat Output Jumper
for Humidity Operation
for Humidity Operation
To control a MISC output for humidification, place the MISC1, MISC2,
or MISC3 jumper on the terminal labeled HUM (see diagram below).
This will supply 24VAC to the selected MISC terminal based on the
humidification programming in the following pages. Only one of the
three outputs (MISC1, MISC2, or MISC3) is required to have this
jumper. For more information regarding the MISC1, MISC2, and
MISC3 outputs, please see section 21.
In the diagram below, the MISC3 jumper
has been set for HUM (humidify) operation.
ELEC
GAS
W3
PROG
HP
HUM
GAS
DEHUM
Y2
B
(MISC1
MISC3
MISC2
MISC1
O
ONLY)
W1
W2
Y1
MISC1
G
RS2
MISC2
MISC3
CK1
RS+5
CKGND
Rs1
R
INSTALL HUMIDITY
MODULE WITH SENSING
RSGND
ELEMENT OUTWARD
C
MISC3
MISC3
OK
TOTALINE
W3
PROG
HUM
DEHUM
MISC3
MISC2
IMPORTANT CAUTION
NEVER PUT MORE THAN ONE JUMPER
ON THE SAME MISC JUMPER BLOCK!
THIS MAY DAMAGE THE THERMOSTAT
AND VOID YOUR WARRANTY
Page 9.2
9
Y2
(MISC1
MISC1
ONLY)