Advanced Setup Table - TOTALINE P374-1900 Owner's Manual

7-day programmable digital thermostat humidity control
Hide thumbs Also See for P374-1900:
Table of Contents

Advertisement

SECTION 24

Advanced Setup Table

Advanced Setup Table
Description
Pg#
Range
Step#
1
Programmable
4.2
Yes/No
Thermostat
2
Auto Changeover
4.3
Yes/No
Thermostat
3
Programmable Fan
7.3
0:00-0:60
7.3
24 Hour
4
Programmable Fan
Start Time
5
Programmable Fan
7.3
24 Hour
Stop Time
6
Fan Off Delay
7.4
0, 30, 60,
90
7
Thermoglow
8.2
Auto/On/
Off
Backlight
8
F or C
8.2
F/C
9.3
Yes/No
9
Humidify with Fan
10
Cool to Dehumidify
10.4
On/Off
11
Maximum Dehum
10.4
0 - 5
Overshoot
12
Reheat Operation
10.5
On/Off
13
DEHUM Terminal
10.6
NO/NC
Polarity
11.2
read only
14
Energy Watch -
Heat Timer
11.3
read only
15
Energy Watch -
Cool Timer
16
Reset Service
11.4
read only
Humidify Icon
16
Reset UV Light Icon
11.5
read only
18
Heatpump Jumper
12.2
read only
Setting
12.2
read only
19
Reversing Valve
Jumper Setting
12.3
read only
20
Electric Heat
21
Dual Fuel Operation
13.2
Off/On
22
13.2
32 - 85
Changeover
Balance Point
23
Minimum Heat/Cool
14.2
0 - 6
Differential
24
Cycles Per Hour
14.3
d1, d, 2-6
14.5
1 - 6
25
Deadband/Temp.
Swing 1st Stage
14.5
0 - 10
26
Deadband/Temp.
Swing 2nd Stage
*Df = Factory Default Setting
*
Description
Pg#
Df
Step#
Yes
27
Deadband/Temp.
14.5
Swing 3rd Stage
Yes
28
Minutes Between
14.6
Stage 1 & 2
0
29
Minutes Between
14.6
7am
Stage 2 & 3
30
2nd Stage turn off at
14.7
9pm
setpoint
31
Programmable
15.3
Output
0
32
Programmable
15.4
Output Polarity
Auto
33
7 Day/1 Day Prog-
15.4
ammable Output
F
34
P
15.4
No
rogrammable Output
Day of the Week
Off
35
P
rogrammable Output
15.4
3
Start Time
36
P
15.5
rogrammable Output
Off
Stop Time
NC
37
P
15.6
rogrammable Output
Temp. Setpoint
- -
38
Thermostat READ
16.3
to RS1
- -
39
Local Sensor
16.4
Averaging
- -
40
Dry Contact
17.2
Operation
- -
41
Dry Contact Polarity
17.2
- -
42
Dry Contact
17.3
Programming
- -
43
Energy Save
18.1
- -
44
Reset Service Filter
19.2
Off
Icon
35
45
Service Filter Run
19.2
Time Set
2
46
UV Light Run-Time
19.3
Set
6
47
Service Humidify
19.4
2
Run-Time Set
2
Page 24.1
TOTALINE
*
Range
Df
0 - 10
2
0-60min
2
0-60min
2
On/Off
Off
Off/Time/
Off
Temp/Aux
NO/NC
NO
7Day/
7-
1Day
Day
Mo - Su
Mo
24 Hour
7am
24 Hour
9pm
35 -125
80
Yes/No
Yes
On/Off
Off
Yes/No
No
NO/NC
NO
Vacation/
Vac-
Service
ation
Pan
Off/On
Off
read only
- -
0 - 1950
0
0 - 1999
0
0 - 1999
0
24

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents