2. Ceiling dimensions and hanging bolt location
I Installation of Unit
Install the unit above the ceiling correctly.
CASE 1
POSITION OF SUSPENSION BOLT
• Apply a joint-canvas between the unit and duct to
absorb unnecessary vibration.
• Apply a filter Accessory at air return hole.
Dimension
A
B
C D
Capacity
36K BTU
1242 1180 492 54 600
• Install the unit leaning to a drainage hole side as
a figure for easy water drainage.
CASE 2
POSITION OF CONSOLE BOLT
• A place where the unit will be leveled and that
can support the weight of the unit.
• A place where the unit can withstand its vibration.
• A place where service can be easily performed.
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
(Unit:mm)
E
F (G) H
I
30
87 830 186
- 16 -
A
B
(G)
H
Drainage hole
M10 Nut
X 4
(Local
M10 SP. washer
X 4
supply)
M10 washer
X 4
M10 washer
X 4
(Local
M10 SP. washer
X 4
supply)
M10 Nut
X 4