Honda CRF250X 2007 Owner's Manual & Competition Handbook page 54

Table of Contents

Advertisement

4. Add coolant to the reserve tank as require to
bring the coolant level to the UPPER level
mark.
5. Install the reserve tank cap (10).
6. Install the left side cover (9), collar (7), seat
mounting bolt (8) and left side cover bolt (6).
Close the air cleaner housing cover (4) and
turn the quick fastener (5) clockwise.
Tighten the seat mounting bolt to the specified
torque:
19 lbf·ft (26 N·m, 2.7 kgf·m)
(4)
(5)
(4) air cleaner housing cover
(5) quick fastener
(6) left side cover bolt
(7) collar
(8) seat mounting bolt
(9) left side cover
(10) reserve tank cap
Cooling System Inspection
1. Check the cooling system for leaks (see the
Honda Service Manual for troubleshooting of
leaks).
2. Check the water hoses (1) for cracks,
deterioration, and radiator hose clamp for
looseness.
3. Check the radiator mount for looseness.
4. Make sure the siphon hose (2) is connected
and not clogged.
5. Check the radiator fins for clogging.
(10)
(9)
6. Check the water leakage check hole (3) below
the water pump cover (4) for leakage. Make
(8)
sure the hole remains open. If water leaks
through the check hole, the water seal is
damaged. If oil leaks through the check hole,
the engine oil seal is damaged. See the Honda
Service Manual or consult your Honda dealer
for replacing the water seal or the engine oil
(7)
seal. Both seals should be replaced at the
same time.
(6)
(1)
(4)
(1) water hoses
(2) siphon hose
(3) water leakage check hole
(4) water pump cover
Servicing Your Honda
Coolant
(2)
(3)
49