Repair Hints
3) During repair it is possible to disconnect the Tuner Board
(pos 1103) and CDC & MPEG Module (pos 1105) unless
the fault is suspected to be in that area. This will not affect
the performance of the rest of the set.
4) Due to the short flex cable wires in the ETF Module, the
pc board should be disconnected and reconnected on
the reverse side of the tape mechanism to keep it
electrically connected during repair. See picture 3.
Note: The flex cables are very fragile, care should be taken
not to damage them during repair. After repair, be
very sure that the flex cables are inserted properly
into the flex sockets before encasing, otherwise faults
may occurs.
Service pos A
Service pos B
2-3
Picture 3
Service pos C
Service pos D
2-3

Hide quick links: