6. ADJUSTMENT PROCEDURE

(1) ALIGNMENT INSTRUCTIONS
EQUIPMENT NEEDEDIMPORTANT
AM Signal Generator1.Check power-source voltage.
FM Signal Generator2.Set the function switch to band
aligned.
Oscilloscope3.Keep the function input as low as possible
to adjust.
VTVM(AC,DC) accurately.
Test loop antenna (MW Adjustnent) 4.Modulation and
modulation frequency.
Dummy antenna(FM Adjustment)
Stereo signal modulator.
Distortion analyzerModulationModulation Frequency.
EQUIPMENT NEEDEDIMPORTANT
AM Signal Generator1.Check power-source voltage.
FM Signal Generator2.Set the function switch to band
aligned.
Oscilloscope3.Keep the function input as low as possible
to adjust.
VTVM(AC,DC) accurately.
Test loop antenna (MW Adjustnent) 4.Modulation and
modulation frequency.
MODULATION
MODULATION
FREQUENCY
MW
30%
400Hz
FM
100%(75KHz)
400Hz
(2) TUNING FREQUENCY RANGE ADJUSTMENT
(FM) DC VOLTMETER
CONNECT TO TEST POINT TP1 and GND
(MW) DC VOLTMETER
CONNECT TO TEST POINT TP1 and GND
ADJUST
ADJUST-
NO
BAND
FREQUENCY
FOR
MENT
1
FM
87.50MHz
1.5V
L4
2
MW
522KHz
1V
L103
DC EVM
UNIT
FM
TP11
AM
GND
GND
(3) MW TRACKING ADJUSTMENT
Signal Generator : Connects to the MW Ant.
Coil through the loop antenna.
Adjust for the indication of VTVM of the wave form of
scope to be maximum.
NO
STEP
FREQUENCY
ADJUST FOR
1
612KHz
Max sensitivity
MW
2
1503KHz
Max sensitivity
3
Repeat steps 1 and 2 several times.
AC EVM
OSCILLOSCOPE
AM-SG
MHz
AM LOOP antenna
OUTPUT
terminal
60cm
(4) FM-RF ADJUSTMENT
Signal Generator : Connects to FM ANT. JACK (FM IN)
through the dummy.
NO
FREQUENCY
ADJUST FOR
ADJUSTMENT
1
90.10MHz
Max sensitivity
L1,L2,L3
2
Repeat step 1 several times
AC EVM
OSCILLOSCOPE
FM-SG
MHz
OUT
UNIT
OUTPUT
terminal
FM ANT
13
(5) FM MONO DISTORTION ADJUSTMENT
DC VOLTMETER
Connect to TP02 (-),TP03 (+) through the chockcoil
(100 H).
Signal Generator
Connect to FM ANT. Jack (FM IN) through thedummy.
Distortion Meter
Connect to the output.
ADJUS-
NO
FREQUENCY
ADJUST FOR
MENT
DC Voltmeter
L102
1
100.10MHz
CT01
2
100.10MHz
min T.H.D
3
Repeat steps 1 and 2 several times
FM-SG
MHz
OUT
TP12
Chassis
TP13
(6) FM STEREO SEPARATION
PILOT
ADJUST FOR
SIGNAL
Different of R and L
ON
Must be maximum
FM-SG
Dummy
FM IN
OUT
EXT
OUT
STEREO
MODULATOR
(7) FM/MW TUNED LEVEL ADJUSTMENT
FM Signal Generator : Connect to FM ANT. Jack (FM IN)
MW Signal Generator : Connect to MW ANT. Coil thriugh
BAND STEP SIGNAL GENERATOR ADJUST FOR ADJUSTMENT
ADJUSTMENT
FM
1
100.10MHz 30dB
T101
2
100.10MHz 30dB
0V
MW
1
999KHz 80dB
T102
2
999KHz 80dB
DC EVM
UNIT
Choke coil
100 H
output
DISTORTION
ANALYSER
ADJUSTMENT
VR03
STEREO
OSCILLOSCOPE
UNIT
OUTPUT
VTVM
VR03
14
through the dummy.
Loop antenna.
TUNED
ON
VR02
TUNED OFF
VR02
TUNED
ON
VR01
TUNED OFF
VR01