Panasonic NE-C1153 Service Manual page 24

Table of Contents

Advertisement

NE-C1153 / NE-C1153C
in a beaker which is graduated to 600cc, and place the
beaker in the center of the oven.
2. Set the radiation monitor to 2450MHz and use it following
the manufacture's recommended test procedure to assure
correct results.
3. When measuring the leakage, always use the 2 inch (5cm)
spacer supplied with the probe.
4. Press the start button and with the magnetron oscillating,
measure the leakage by holding the probe perpendicular to
the surface being measured.
1. Measurement with the outer panel removed.
Whenever you replace the magnetron, measure for
radiation leakage before the outer panel is installed and
after all necessary components are replaced or adjusted.
Special care should be taken in measuring around the
magnetron.
Avoid contacting any high voltage parts.
2. Measurements with a fully assembled oven.
After all components, including the outer panel are fully
assembled, measure for radiation leakage around the door
periphery, the door viewing window, the exhaust opening
and air inlet openings.
12.3. Record keeping and
notification after measurement
1. After any adjustment or repair to a microwave oven, a
leakage reading must be taken. Record this leakage
reading on the repair ticket even if it is zero.
A copy of this repair ticket and the microwave leakage
reading should be kept by repair facility.
2. Should the radiation leakage be more than 2mw/square
centimeter after determining that all parts are in good
condition, functioning properly, and genuine replacement
parts as listed in this manual have been used, immediately
notify PASC or PSC.
WARNING
12.4. At least once a year, have the
radiation monitor checked for
calibration by its
manufacturer.