Clearing the Result Display
To clear the result display to "0", press the buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as
shown below:
1. If the screen is already displayed, proceed to step 3. If not, Power off (Set to Standby model).
t
2. Press
8 t ENTER
3. Press
Clearing the Self-Diagnostic Screen
The self diagnosis screen display is cleared by turning off the set using the Remote Commander or the power switch.
Self-Diagnostic Circuit
Self-Diagnosis Function Operation
3 :
Lamp cover
4 :
Fan
4 :
Temp
5 :
Lamp driver
6 :
Low B error
7 :
Audio
8 :
D-OVP
10 :
ATSC-OVP
LAMP :
Lamp
5 t
– t 1 ON
The rib at the back of the lamp cover closes the SW on the T board to ground pin 3 of
CN8001.
It is monitored by the DE-micro (pin 94 of IC6902) and turns off the lamp when it is opened.
Fan rotation is detected by "FAN-PROT" and the DE-micro (pin 92 of IC6902) turns off the
lamp when it is "high".
When the temperature sensor on the H3 board (WE models) or H4 board (WF/XS models)
detects high temperature, or IIC-E line connector (CN6022:G2 board, CN44:H3board/
H4board) is not seated securely, the DE-micro turns off the lamp.
When the "LAMP-PROT" (pin 95) is low, the lamp is not turned on. If the "LAMP-HV-
DET"(pin 96) is low at the same time, it is classified as no high voltage of the lamp driver.
When no "DD 6V " is detected, pin 129 of TV-micro is low and it turns off the main power.
When DC voltage is detected at the speaker or woofer outputs, pin 128 of TV-micro is low
and it turns off the main power.
When overvoltage of "+3.3V" or "+2.5V" is detected, pin 126 of TV-micro is low and it
turns off the main power.
When no "Digital Module 5V" is detected, pin 127 of TV-micro is low and it turns off the
main power.
When the "LAMP-PROT" (pin 95) is low, the lamp is not turned on. If the "LAMP-HV-
DET" (pin96) is high at the same time, it is classified as no lamp or a dead lamp.
KDF-55WF655K/60WF655K
– 8 –
RM-KD001
RM-KD001