Measurements Setup, Service Aid Lead Free Requirements - Philips HTS3300/98 Service Manual

Philips dvd receiver service manual
Hide thumbs Also See for HTS3300/98:
Table of Contents

Advertisement

EN 4
2.
2. Measurements Setup, Service Aid & Lead Free Requirements
MEASUREMENT SETUP
Tuner FM
RF Generator
e.g. PM5326
Use a bandpass filter to eliminate hum (50Hz, 100Hz) and disturbance from the pilottone (19kHz, 38kHz).
Tuner AM (MW,LW)
RF Generator
e.g. PM5326
Frame aerial
e.g. 7122 707 89001
To avoid atmospheric interference all AM-measurements have to be carried out in a Faraday´s cage.
Use a bandpass filter (or at least a high pass filter with 250Hz) to eliminate hum (50Hz, 100Hz).
CD
Use Audio Signal Disc
SBC429 4822 397 30184
(replaces test disc 3)
DUT
L
R
HTS3300
Measurements Setup, Service Aid & Lead Free Requirements
Bandpass
DUT
250Hz-15kHz
e.g. 7122 707 48001
Bandpass
250Hz-15kHz
DUT
e.g. 7122 707 48001
S/N and distortion meter
e.g. Sound Technology ST1700B
S/N and distortion meter
e.g. Sound Technology ST1700B
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter
LF Voltmeter
e.g. PM2534
S/N and distortion meter
e.g. Sound Technology ST1700B
LF Voltmeter
e.g. PM2534
Recorder
Use Universal Test Cassette CrO2 SBC419 4822 397 30069
or Universal Test Cassette Fe
LF Generator
e.g. PM5110
SBC420 4822 397 30071
DUT
L
R
S/N and distortion meter
e.g. Sound Technology ST1700B
LEVEL METER
e.g. Sennheiser UPM550
with FF-filter

Advertisement