Sharp R-430CK Service Manual page 25

Table of Contents

Advertisement

Pin No.
Signal
24
P25
OUT
25-26
P26-P27
OUT
27-29
P30-P32
OUT
30-34
P33-P37
OUT
35
CVCC
36
VSS
37-38
V3-V2
39-40
V1-V0
41
VCC
42-45 COM4-COM1 OUT
46-65 SEG1-SEG20 OUT
66-79
P74-P91
OUT
80-85
OUT
SEG35-SEG40
86
OUT
P40
87
P41
88 P42
INSignal similar to AN10.
89
IRQ0
90
AVCC
91
AN0
92
AN1
I/O
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cooking
and "H" level while not cooking. In other cooking
modes (variable cooking) the signal turns to "H"
level and "L" level in repetition according to the
power level.
Terminal not used.
Terminal not used.
Used for initial balancing of the bridge circuit (absolute humidity sensor).
IN
Connected to GND.
IN
Power source voltage: -5.0V.
The power source voltage to the LSI is input to VSS terminal. Connected to VC
IN
Terminal not used.
Power source voltage input terminal.
Standard voltage for LCD. Connected to GND.
IN
Power source voltage: GND (0V).
The power source voltage to drive the LSI is input to VCC terminal.
Terminal not used.
Terminal not used.
Data output terminal to LCD driver IC3
Terminal not used.
Terminal not used.
IN
Signal similar to AN10.
When either G13 line on key matrix is touched, a corresponding signal will be input into P41.
When either G12 line on key matrix is touched, a corresponding signal will be input into P42.
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
IN
A/D converter power source voltage.
The power source voltage to drive the A/D convertor built into LSI. connected to GND.
IN
Used for initial balancing of bridge circuit (absolute humidity sensor). This input is an
analoge input terminal from the AH sensor circuit, and connected to the A/D converter
built into the LSI.
IN
AH sensor input.
This input is an analoge input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
Description
(ON and OFF times for other power level.)
23
OFF
P-HI
ON
OFF
OFF
24 sec.
P-70
8 sec.
ON
16.7 msec.
R-430CK
R-430CW
R-430CD
H : GND
L : -5V
H : GND
L : -5V
H : GND
L : -5V