Power The Thermostat; Wiring 24 Vac Common; Mount Thermostat To Wallplate; Installing Batteries - Honeywell TH5110D Installation Instructions Manual

Non-programmable thermostat
Hide thumbs Also See for TH5110D:
Table of Contents

Advertisement

TH5110D NON-PROGRAMMABLE THERMOSTAT

POWER THE THERMOSTAT

You can choose from three methods to power the
thermostat:
• Batteries only (AAA alkaline).
• 24 Vac common wire only.
• 24 Vac common wire with battery backup (AAA
alkaline).
NOTE: Battery backup prevents blank displays during
power interruptions.

Wiring 24 Vac Common

• Single-Transformer System—Connect the common
side of the transformer to the C screw terminal of the
thermostat wallplate. Leave the metal jumper in place
between Rc and R.
• Two-Transformer System—Connect the common side
of the cooling transformer to the C screw terminal of
the thermostat wallplate. Remove the metal jumper
between Rc and R.

Installing Batteries

Install two AAA alkaline batteries on the back of the
thermostat as marked on the battery holder. See Fig. 14.
NOTE: After the thermostat is mounted on the
wallplate, the thermostat does not require
removal from the wallplate to replace the
batteries. Refer to the enclosed Operating
Instructions, 69-1713, for more information on
the removable battery holder.
BATTERY HOLDER
BATTERIES
Fig. 14. Installing batteries.
69-1712—1
BACK OF THERMOSTAT
M22056

Mount Thermostat to Wallplate

1. Align the four tabs on the wallplate with the four
slots on the back of the thermostat. Push the
thermostat straight onto the wallplate until it snaps
into place. See Fig 15.
WALLPLATE
TABS
Rc
R
Y
C
(O/B)
W
G
TABS
Fig. 15. Mount thermostat to wallplate.
6
SLOTS ON
BACK OF
THERMOSTAT
M22078