Troubleshooting - Coleman PMP3000 Owner's Manual

3000 watt power inverter
Hide thumbs Also See for PMP3000:
Table of Contents

Advertisement

Available languages

Available languages

In Review
• Never attempt to operate the inverter from any other power source other than
a 12-volt battery.
• When connecting and using the inverter, make sure that the inverter is
positioned far away from any potential source of flammable fumes or gases.
• Make certain that the power consumption of the equipment you wish to
operate is compatible with the capacity of the inverter. Do not exceed
3000 watts in total power, or 1600 watts for each individual AC outlet.
• When attempting to operate battery chargers, monitor the temperature of the
battery charger for approximately 10 minutes. If the battery charger
becomes abnormally warm, disconnect it from the inverter immediately.
• Use only 30 amp spade type fuses for the inverter.
• When operating the inverter with an automobile or marine battery, start the
engine every 30 to 60 minutes and let it run for approximately 10 minutes to
recharge the battery.
• In the event of a continuous audible alarm or an automatic shut down of the
unit, turn the inverter OFF immediately. Do not turn the inverter ON again
until the source of the problem has been identified and corrected.
• To avoid battery drain, always disconnect the inverter when not in use.
• Do not expose the inverter to rain or moisture.
• Avoid placing the inverter near sources of heat or in direct sunlight.
• While in use, make sure that the inverter is properly ventilated.
• For best operating results, make sure the unit is placed on a flat surface.
PMP3000 Models
Modelos PMP3000
7

Troubleshooting

PROBLEM: Low or No Output Voltage
Reason
Poor contact with
battery terminals.
Using incorrect type of
voltmeter to test
output voltage.
PROBLEM: Red LED On
Reason
Battery voltage below
10.0 ± 0.5 volts.
Equipment being operated
draws too much power.
Inverter is too hot (thermal
shutdown mode).
Unit may be defective.
Owner's Manual
Manual del Usuario
Solution
Clean terminals
thoroughly. Reattach
battery clips.
Use true RMS reading meter.
Solution
Recharge or replace battery.
Use a higher capacity inverter
or do not use this equipment.
Allow inverter to cool.
Check for adequate ventilation.
Reduce the load on the
inverter to rated continuous
power output
See Warranty and call
Customer service at
1-888-231-4022.
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents