Servicing The Thermostat; Cycle Rate Adjustment - Honeywell T8095A/191108AJ Owner's Manual

Heating-only thermostat and wallplate or heating/cooling thermostat and subbase
Table of Contents

Advertisement

Servicing the Thermostat

Cycle Rate Adjustment

(T8095A only)
The equipment should cycle on and off just
enough to keep the room temperature close to
the temperature lever settings.
If the thermostat seems to cycle the heating
system too fast or too slow, adjust the cycle rate
by moving the anticipator setting lever one
indicator mark at a time (Fig. 6). Observe the
heating system operation after each adjustment.
NOTE: Most hot water systems require a setting
of 1.2A.
ANTICIPATOR
SCALEPLATE
ANTICIPATOR
SETTING LEVER
Fig. 6—Heat Anticipator Setting.