LG LCG3091ST Service Manual page 44

Hide thumbs Also See for LCG3091ST:
Table of Contents

Advertisement

C. Install the LP orifice spuds into their correct positions as showen below picture and tables.
D. To prevent leakage, make sure the orifice spuds are securely screwed intothe gas supply tubes.
E. For the Double burner(center) three orifice spuds will be need.
BURNER OUTPUT RATINGS;BTU/HR
LP or Propane Gas, 10~W.C.P
MODEL
BTU RATE
LCG3691ST LCG3091ST LCG3691ST LCG3091ST
BURNER
LF
9100
LR
9100
RR
5000
RF
9500
INNER
CTR
15000
OUTER
F
J
F
A
D
A
Copyright © 2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
CONVERSION TO LP GAS
ORIFICE CODE
9100
F
F
9100
F
F
5000
G
G
9500
H
H
J
J
15000
K
K
K
G
H
E
B
C
BURNER OUTPUT RATINGS;BTU/HR
Natural Gas, 5" W.C.P
F
MODEL
BTU RATE
LCG3691ST LCG3091ST LCG3691ST LCG3091ST
BURNER
LF
9100
J
LR
9100
RR
5000
F
RF
12000
INNER
CTR
19000
OUTER
A
D
A
-44-
K
G
ORIFICE CODE
9100
A
A
9100
A
A
5000
B
B
H
12000
C
C
D
D
19000
E
E
E
B
C
LGE Internal Use Only

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lcg3691st