LOADING AGING MODE
• This mode is used for repeating loading operations continuously.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1. Set a disc in the DISC 1 slit.
2. With the power ON, while pressing the GROUP 2 button and
§ OPEN/CLOSE button, press the +100 button.
3. When the mode is set, both the · and P indicators will
start to blink.
4. When the · button is pressed, only the · indicator will
blink and aging starts.
5. To end the mode, press the 1/u button or disconnect the power
cord from the outlet.
The error codes displayed during operations and when errors occur
are the same as the "AGING MODE" described earlier.
TABLE AGING MODE
• This mode is used for rotating the table randomly.
• Aging will be performed continuously unless an error occurs.
• When an error occurs, the error code will be displayed on the
fluorescent indicator tube.
Procedure:
1. Set discs in slits 1, 2, 99, 100, and 200.
2. With the power ON, while pressing the GROUP 3 button and
§ OPEN/CLOSE button, press the +100 button.
3. When the mode is set, both the · and P indicators will
start to blink.
4. When the · button is pressed, only the · indicator will
blink and aging starts.
5. To end the mode, press the 1/u button or disconnect the power
cord from the outlet.
During aging, operations will be carried out sequentially in the or-
der of No. 1, No. 2, No. 100, No. 99, and No. 200 slits.
The error codes displayed during operations and when errors occur
are the same as the "AGING MODE" described earlier.
DOOR POP UP AGING MODE
• This mode is used for performing aging of the CD pop up part
and door open/close.
It is used for checking if operations are performed normally.
Method:
1. To select a slot to be aged, press the § OPEN/CLOSE button
and rotate the DISC/CHARACTER knob with the front door
opened to select a number.
2. With the power ON, while pressing the GROUP 4 button and
§ OPEN/CLOSE button, press the +100 button.
3. When the · button is pressed, aging starts, and door open/
close and up/down operations of the pop up part are performed
continuously.
4. To end the mode, press the 1/u button.
If DISC is not selected at step 1, aging will be performed at the 192
slot.
The number of times aging is performed will be displayed on the
fluorescent indicator tube during operations.
TABLE ROTATION MODE
• This mode is used for electrical adjustments. Refer to the section
on Electrical Adjustments.
TITLE MEMO SHIFT MODE
• This mode is used for writing title memo information recorded in
this unit in a different unit.
Use it for transferring disc memo contents written by the cus-
tomer to the new units when replacing the unit, etc.
Connection:
This unit
(Copy source)
COMMAND MODE: CD3
CONTROL A1 II
Procedure:
1. Connect two units using the CONTROL A1 II connection cord
shown in the figure.
2. Set the COMMAND MODE switch of the copy source unit to
CD3 and the COMMAND MODE switch of the copy desti-
nation unit to CD1 .
3. With the power on, while pressing the GROUP 7 button and
§ OPEN/CLOSE button of the copy destination unit, press
the +100 button.
4. When the data has been transferred, the fluorescent indicator
tube displays "complete" for about 1 second.
MODEL NAME DISPLAY
• Model names can be displayed on the fluorescent indicator tube
for checking the microprocessor model setting, etc.
Procedure:
With the power ON, while pressing the GROUP 1 and · but-
tons, press the +100 button.
The model name is displayed on the fluorescent indicator tube.
MICROPROCESSOR VERSION DISPLAY
• The microprocessor version can be displayed on the fluorescent
indicator tube.
Procedure:
With the power ON, while pressing the GROUP 2 and · but-
tons, press the +100 button.
The microprocessor version is displayed on the fluorescent indica-
tor tube.
ALL LIT MODE
• This mode is used for lighting the whole fluorescent indicator
tubes and LEDs.
Procedure:
With the power ON, while pressing the GROUP 3 and · but-
tons, press the +100 button.
Both the fluorescent indicator tubes and LEDs will light up com-
pletely.
To end this mode, press the 1/u mode.
– 12 –
Flow of data
Another unit
(Copy destination)
COMMAND MODE: CD1
CONTROL A1 II connection cord provided