Projection Lamp - Optoma ES520 Serivce Manual

Data projector
Hide thumbs Also See for ES520:
Table of Contents

Advertisement

Delta Elec. Inc.
ES520 & EX530
ver.02

8. Projection Lamp

8-1. Replacing the Projection Lamp
The projection lamp should be replaced when it burns out. It should only be replaced with a
certified replacement part, which you can order from your local dealer.
Important:
1. The lamp contains a certain amount of mercury and should be disposed according to local
ordinance regulations.
2. Avoid touching the glass surface of the new lamp: Doing so may shorten its operation life.
Warning:
Be sure to turn off and unplug the projector at least 30 minutes before replacing the lamp.
Failure to do so could result in a severe burn.
1. Loosen the two captive screws on the lamp compartment cover.
2. Remove the lamp compartment cover.
3. Remove the two screws from the lamp module.
4. Lift the module handle up and pull firmly on the module handle to remove the lamp module.
5.
Insert the replacement lamp and push down firmly.
Tighten the captive screws to hold the lamp in place.
6.
Replace the lamp compartment lid and tighten the captive screws.
Company Confidential
Optoma___________________
Delta________________
92
2008/09/17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp-2512Ex530Dp-3511

Table of Contents