Optoma ES520 Serivce Manual page 21

Data projector
Hide thumbs Also See for ES520:
Table of Contents

Advertisement

Delta Elec. Inc.
Check the
projection
Screen
Yes
Check using all black/white screens with
PC connection
Yes
Are abnormalities
noticeable on
projection screen?
No
Does the lamp
go off during
operation?
No
Yes
Is
LAMP
Light again?
No
Over Temp LED:
ON
No
System OK
Normal operation
Company Confidential
21
ES520 & EX530
• Black lines on screen (horizontal and vertical)
→ DMD Set malfunction
Yes
• Missing pixels (Missing white: 1 or more, missing black: 5 or
more, or sequence missing pixels)
→ DMD Set malfunction
• Shadows on screen
→ Dirt on DMD/projection lens surface
• Bluish shadows on corners of screen (during white screen
display)
→ Shifted optical axis of Lens Base Unit
Yes
• Lamp malfunction
• Power Supply Unit malfunction
• Temperature protector operated due to the increase in
Yes
temperature based on operating environment
• Temperature protector operated due to blocked suction and
exhaust holes or dirty fan
Optoma___________________
No
No
No
Delta________________
ver.02
2008/09/17