Step 5. Install The Batteries - Honeywell CT3500 Owner's Manual

Weekday, saturday and sunday programmable heat and/or cool low voltage (20 to 30 vac) thermostat and wallplate
Hide thumbs Also See for CT3500:
Table of Contents

Advertisement

Terminal on Old Thermostat
a
R, RH
, 4, V
a
Rc, R
W, W
, H
1
Y, Y
, M
1
G, F
O
b
B
c
c
b
C
, X
, B
W
, H
2
2
Y
2
a
If both RH and R terminals are present on existing thermostat, remove jumper and connect Rh to R and R to Rc.
b
Do not connect both O and B when wiring to a single stage heat pump. Connect O to O. Tape off B.
c
Tape off end of the wire with electrical tape and push the taped wire back into the wiring hole in the wall.

STEP 5. INSTALL THE BATTERIES

IMPORTANT
Three fresh AA alkaline batteries must be installed for pro-
gramming and operation of the thermostat and the heat-
ing/cooling system.
q
Install the batteries in the wallplate so the positive terminals all
point up (see illustration).
Table 2. Terminal Designations on Old and New Thermostats.
Connect To
R
Rc
W
Y
G
O
b
B
Do not connect.
Do not continue installation.
Call 1-800-468-1502.
Power
Power for cooling
Heat
Cooling
Fan
Changeover in cool. (Single stage heat pump only).
Changeover in heat. (Single stage heat pump only).
Transformer common
Second stage heat.
Second stage cool.
INSTALL 3 AA ALKALINE BATTERIES
AS SHOWN, POSITIVE (+) TERMINALS
TOWARD TOP.
9
Description
WALLPLATE
B
R
RC
O
W
Y
G
69-1199—4
M10622

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ct3595

Table of Contents