PROCEDURE
LETTER
11) Reconnect all leads removed from components during testing.
12) Re-install the outer case (cabinet).
13) Reconnect the power supply cord after the outer case is installed.
14) Run the oven and check all functions.
The touch control section consists of the following units as
shown in the touch control panel circuit.
(1) Key Unit
(2) Control Unit
The principal functions of these units and their related
signals are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit through R00, R01, R03, R20
and R21.
When a key pad is touched, a signal is completed through
the key unit and passed back to the LSI through R23, K00,
K01 and K02 to perform the function that was requested.
Control Unit
Control unit consists of LSI, ACL circuit, indicator circuit,
power source circuit, relay circuit, buzzer circuit and syn-
chronizing signal circuit.
1) ACL
This circuit generates a signal which resets the LSI to the
initial state when power is supplied.
2) Indicator Circuit
This circuit consists of 4-digits, 12-segments and 3-
common electrodes using a Liquid Crystal Display.
TEST PROCEDURES
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOUCH CONTROL PANEL
COMPONENT TEST
3) Power Source Circuit
This circuit generates voltage necessary in the control
unit from the AC line voltage. In addition, the synchronizing
signal is available in order to compose a basic standard
time in the clock circuit.
Symbol
Voltage
VC
4) Relay Circuit
To drive the magnetron, fan motor, turntable motor and
light the oven lamp.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
audible sounds (key touch sound and completion sound).
6) Synchronizing Signal Circuit
The power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit. It accompanies a very small error because it
works on commercial frequency.
7) Door Sensing Switch
A switch to "tell" the LSI if the door is open or closed.