SERVO BOARD
IC201
Pin No.
Pin Name
1
A3
2
A4
3
A5
4
A6
5
A7
6
A8
7
A9
8
A10
9
A11
10
A12
11
WE
12
NC
13
NC
14
LED-PLAY
15
LED-PAUSE
16
LED-FILTER
17
SPDL-MUTE
18
SHIFT-ON/OFF
19
VOL UP
20
VOL DOWN
21
BLANK
22
FL D0
23
FL D1
24
FL D2
25
FL CLK
26
FL WR
27
SENSER SW
28
SENSER
29
LIMIT OUT
30
RESET
31
XTALI
32
XTALO
33
VSS
34
TX
35
TEX
36
AVSS
37
AVREF
38
K0
39
K1
40
K2
CXP84124-068Q (SYSTEM CONTROLLER)
I / O
O
O
O
O
O
Address signal output to the static RAM (IC202)
O
O
O
O
O
O
Write enable signal output to the static RAM (IC202)
O
Not used (open)
O
Not used (open)
( LED (D871) drive signal output terminal
O
O
P LED (D872) drive signal output terminal
O
FILTER LED (D873) drive signal output terminal
O
Mute signal output to the spindle motor driver (IC104, 105)
O
Reset signal output to the CXD2562Q-CS (IC603)
O
Volume up control signal output to the volume control motor driver (IC350)
O
Volume down control signal output to the volume control motor driver (IC350)
O
Blank signal output to the fluorescent indicator tube driver (IC801 to IC803)
O
Serial data output to the fluorescent indicator tube driver (IC803)
O
Serial data output to the fluorescent indicator tube driver (IC802)
O
Serial data output to the fluorescent indicator tube driver (IC801)
Serial data transfer clock signal output to the fluorescent indicator tube driver (IC801 to
O
IC803)
O
Read/write select signal output to the fluorescent indicator tube driver (IC801 to IC803)
O
On/off control signal output to the stabilizer detect sensor (IC261)
I
Detect signal input from the stabilizer detect sensor (IC261)
Detection input from the sled limit-out detect switch (S21)
I
The optical pick-up is outer position when "L"
System reset signal input from the reset signal generator (IC91)
I
For several hundreds msec. after the power supply rises, "L" is input, then it changes to "H"
I
Main system clock input terminal (4 MHz)
O
Main system clock output terminal (4 MHz)
Ground terminal
O
Sub system clock output terminal
I
Sub system clock input terminal
Ground terminal (for A/D converter)
I
Reference voltage input terminal (+5V)
I
Key input terminal (A/D input)
Key input terminal (A/D input)
I
FILE, EDIT/TIME FADE, TIME, REPEAT, P MODE keys (S851 to S855) input
Key input terminal (A/D input)
I
CHECK, CLEAR, FILTER, 0, ) , PUSH ENTER keys (S884 to S888, RV870) input
Function
"H": LED on
"H": LED on
Not used (open)
Not used (fixed at "L")
ERASE key (S850) input
– 57 –
"H": LED on
"L": reset
"H": on
"H": on
"L": reset