Spark Arrester Maintenance
If the generator has been running, the muffler will be very hot. Allow to cool
before proceeding.
ps7EE-j
The spark arrester must be serviced every 100 hours to
maintain its efficiency.
1.
2.
Remove the two 6 mm bolts and the two 6 mm cap nuts.
Remove the cover.
6 mm BOLTS
6 mm CAP NUTS
Remove the two 6 mm nuts and the 6 mm bolts.
Remove the muffler from the exhaust pipe carefully to avoid damaging the
spark arrester screen.
6mm
6mm
NUTS
BOLT
30