5. GENERATOR
USE
N
To prevent electrical
shock from faulty appliances, the generator
should be grounded.
Connect
a length of heavy wire between the ground
terminal and the ground source.
CAUTION:
l
Limit operation
requiring
maximum
power (EMS4000
: 4.0 kW, EMS4500 :
4.5 kW) to 30 minutes.
For continuous
operation,
do not exceed the rated power (EMS4000
: 3.8
kW, EMS4500 : 4.0 kW).
In either
case, the total
wattage of all appliances
connected
must be
considered.
l
Do not exceed the current limit specified for any one receptacle.
l
Connections
for standby
power to household
circuits
must be made by
a qualified
electrician
and must comply with all applicable laws and electri-
cal codes. Improper
installation
may result in personal injury or damage to
equipment
or property.
Auto-throttle
system
With the switch in the AUTO position,
engine speed is automatically
reduced
to an idle when all loads are turned off or disconnected.
When appliances are
turned on or reconnected,
the engine resumes the rated speed. At OFF, the
auto-throttle
system does not operate.
NOTE:
l
AUTO is recommended
to minimize fuel consumption.
l
The auto-throttle
system will not respond to electrical
loads of less than 1
ampere.
l
The system is not effective for use with appliances
that require only mo-
mentary power. To avoid extended warm-up periods, keep the switch OFF
until the engine reaches operating temperature.
16