Batteries dead!
Please charge now!
This display is shown briefly, immediately before the unit shuts down. The AQL-Tx-
RF-PS-x will not operate again (to protect the batteries) until it is plugged into the
charger. It can be used immediately while connected to the charger.
1.
Can't find the "Teach Wireless" display: From the Aqua Logic control (or any
direct wired display/keypad) press the "menu" button (possibly more than once)
until "Settings Menu" is displayed. Next, press the "<" or ">" buttons (possibly
more than once) until the "Teach Wireless" display appears. If you get to the
point where "Settings Menu" appears again, then this means that the Aqua
Logic control unit is not communicating with the base receiver. Check that the 4
wire cable from the base receiver is plugged into the "wireless" connector on the
main printed circuit board. If this connector is already plugged in (for more than
30 seconds), then call Goldline Technical Service for assistance.
2.
"Teach Wireless" failed: Ensure that the remote is powered when pressing the
button. This is indicated by any message on the display of the remote. If the
remote is powered, then the next most likely cause is that the distance between
the base receiver and the remote is too great—try moving the remote closer to the
receiver. Lastly, there may be other equipment in the neighborhood that is using
the same frequency. To see if this is the case, go to the Settings Menu/Wireless
Channel and select another channel. Note that after you change the channel you
will have to "re-teach" every wireless remote device in the system.
3.
Unreliable communication with remote devices: The most likely cause is that
the distance between the base receiver and the remote is too great—try moving
the remote closer to the receiver. Lastly, there may be other equipment in the
neighborhood that is using the same frequency. To see if this is the case, go to
the Settings Menu/Wireless Channel and select another channel. Note that after
you change the channel you will have to "re-teach" every wireless remote device
in the system.
4.
Wireless display/keypad not functioning (no display, no LEDs illuminated):
AQL-WW-RF-PS-x models: If the display/keypad located on the main unit is
working correctly, check that there is input power to the wireless display/key-
pad. Make sure that the wall mount power supply is plugged into an active
120VAC outlet and its output connector is plugged into the wireless remote
display/keypad.
AQL-Tx-RF-PS-x models: If the display/keypad located on the main unit is
working correctly, check that there is input power to the wireless display/key-
pad. Plug the charger into an active 120VAC outlet and its output connector into
the wireless remote display/keypad. If this doesn't work, plug charger into the
unit, plug the charger into an active 120VAC outlet, wait 5 seconds, unplug the
charger, wait 5 seconds, and then plug it back in again.