Spark arrester maintenance
w
If the generator has been running, the muffler
will be very hot.
Allow
it to cool before proceeding.
CAUTION: The spark arrester must be serviced every 100 hours to maintain
its efficiency.
1. Loosen the bolts and nuts and remove the muffler.
2. Loosen two 8mm bolts to remove the exhaust pipe.
3. Check the muffler exhaust port for carbon deposits; clean if necessary.
4. Remove the spark arrester from the muffler.
Clean the screen and inspect it for damage. Replace if necessary.
5. Install the spark arrester in the muffler.
Install the muffler
and gasket and tighten
the
bolts and
nuts securdy.