Resetting Switchlinc Timer To Its Factory Default Settings; X10 Programming Options; Setting The X10 Address; Removing The X10 Address - INSTEON SwitchLinc 2476ST Owner's Manual

Countdown wall switch timer (nondimming)
Table of Contents

Advertisement

Resetting SwitchLinc Timer to its Factory Default Settings

The factory reset procedure can be used to clear the SwitchLinc memory of all INSTEON Links,
programmed On-Levels and Ramp Rates, X10 addresses, etc.
1) If you are using a Controller to control SwitchLinc, be sure to Unlink it from the Controller. See
Unlinking SwitchLinc Timer from an INSTEON Controller.
2) If you are using SwitchLinc to control any Responders, Unlink them from SwitchLinc. See Unlinking
an INSTEON Responder from SwitchLinc Timer.
3) Gently pull the Set button out as far as it will go (about
The load and the SwitchLinc Status LED will turn off
4) Wait 10 seconds. Then, push the Set button all the way down and hold until it beeps (3 seconds).
The SwitchLinc Status LED will turn on. After a few seconds, SwitchLinc will double-beep and its
load will turn on.

X10 PROGRAMMING OPTIONS

SwitchLinc is X10 ready, meaning that it can respond to X10 commands from X10 controllers and send
commands to X10 devices. However, to operate SwitchLinc in X10 mode, you must first set up an X10
address. As it ships from the factory or after a factory reset procedure, SwitchLinc will not have an X10
address set up.

Setting the X10 Address

1) Set SwitchLinc to Linking Mode by pressing & holding the paddle top until it beeps (10 seconds)
The SwitchLinc Status LED will begin blinking
You will have 4 minutes to complete the next step before Linking Mode automatically times out.
2) Using an X10 controller, send the X10 address you want to assign and the ON command three times
For example, to assign the address A1, you would send "A1 ON A1 ON A1 ON."
3) Once SwitchLinc has received the sequence, it should exit Linking Mode
SwitchLinc will double-beep and its Status LED will stop blinking and turn on solid

Removing the X10 Address

If you are no longer going to control SwitchLinc with an X10 address, it is very important that you Unlink it.
Otherwise, SwitchLinc will still respond to X10 commands and may cause SwitchLinc to turn on by itself.
1) Set SwitchLinc to Linking Mode by pressing & holding the paddle top until it beeps (10 seconds)
The SwitchLinc Status LED will begin blinking
2) Set SwitchLinc to Unlinking Mode by pressing & holding the paddle top until it beeps again
The SwitchLinc Status LED will continue blinking
You will have 4 minutes to complete the next step before Unlinking Mode automatically times out.
3) Using an X10 controller, send the X10 address you wish to remove and the ON command three
times
For example, to remove the address A1, you would send "A1 ON A1 ON A1 ON".
4) Once SwitchLinc has received the sequence, it should exit Linking Mode
SwitchLinc will double-beep and its Status LED will stop blinking and turn on solid
SwitchLinc Timer Owner's Manual
Page 18 of 23
1
/
inch) to remove all power from SwitchLinc
8