Changing the Paddle and LED Colors ....................19 ABOUT INSTEON ............................20 Using Dual-Band INSTEON Devices to Upgrade Your Network............. 20 Important Note about INSTEON Networks; Split Single-Phase vs. 3-Phase Installation ....... 20 Further Enhancing Reliability ........................21 ADDITIONAL RESOURCES ........................21 TROUBLESHOOTING..........................
Set button (push) Air gap (pull) Key SwitchLinc Timer Features • Once installed, setup is easy – Links to other INSTEON devices in minutes • Controls standard, wired-in incandescent lighting and inductive loads up to 480 Watts, 15 Amps •...
Reliable, because every INSTEON device works as a network repeater, ensuring your commands will not be lost. Affordable, because INSTEON can be integrated into any number of devices easily and at a very low cost. An INSTEON home grows in value with each added INSTEON device, making life more convenient, safe, and fun.
INSTEON Gold Support Line or consult an electrician. • Each SwitchLinc is assigned a unique INSTEON ID, which is printed on the device’s label. It is recommended that you prepare a list of all the devices you are installing, including their INSTEON ID and their location (e.g., 01.F7.G5, Mike’s bedroom light).
SwitchLinc Timer Owner’s Manual Installing SwitchLinc Timer 1) At the circuit breaker or fuse panel, disconnect the power for all of the circuits in the switch junction box. Verify that the power is off by trying to turn on the lights controlled by the switches. 2) Remove the wallplate from the switch you are replacing.
SwitchLinc Timer Owner’s Manual Installing SwitchLinc Timer in a Multi-Way Circuit Understanding Multi-Way Circuits If more than one switch controls a single set of lights (called a load), the switches are part of a multi-way circuit. A 3-way circuit uses two switches to control a load, a 4-way circuit uses three switches, and so forth.
Page 8
All SwitchLincs, whether they are Primaries or Secondaries, must be connected to NEUTRAL and to GROUND. Note that the switches you are replacing will not normally have a connection to NEUTRAL. If there is no NEUTRAL wire in the junction box, please consult an electrician or call INSTEON Gold Support Line at 800-762-7845.
Page 9
SwitchLinc Timer Owner’s Manual Step-by-Step Instructions for Installing Multi-Way SwitchLincs When replacing a 3-way mechanical switch, each switch will have three wires connected to it from the junction box. Four-way or greater circuits will have four wires connected to the switches in the center of the circuit. For this tutorial, we will follow the most commonly used wire colors for homes in North America.
Page 10
Primary’s NEUTRAL and GROUND wires. Repeat steps 5 and 6 with the SwitchLinc Secondary. Complete installation. Return to Installing SwitchLinc Timer and continue on from step 5. Link the SwitchLincs. See Cross-Linking INSTEON Devices to complete the virtual 3-way Cross- circuit.
Page 11
SwitchLinc Timer Owner’s Manual Special Treatment for 4- or More-Way Circuits If your lighting circuit includes more than two switches controlling a single set of lights, those extra switches will have four wires connected to them. Two of the wires are TRAVELERS from the preceding switch and the other two are TRAVELERS to the next switch in the chain.
SwitchLinc Timer Owner’s Manual USING SWITCHLINC TIMER Using the Paddle The paddle top makes the load and all Linked Responders turn on while the paddle bottom makes the load and Linked Responders turn off. • Press & hold the paddle top until the load turns on (2 seconds) to use SwitchLinc like a standard switch, keeping the load on until you turn it off •...
Unlinking an INSTEON Responder from SwitchLinc Timer If you are no longer going to use an INSTEON Responder that has been Linked to SwitchLinc, it is very important that you Unlink it. Otherwise, SwitchLinc will retry any commands repetitively, thus slowing down the system.
Controller. INSTEON scenes are very easy to set up – just Link more than one Responder to the same On/Off or Scene button on a Controller. Then, when you tap any of the Linked buttons on the Controller, all of the INSTEON devices Linked in the scene will respond as a group.
Mode. If the Controller does not have a Set button, tap the same On or Scene button you used to put the Controller into Linking Mode. 6) Test that the INSTEON scene is working properly by tapping the button you just Linked to on the Controller Multi-Unlinking Multi-Unlinking Mode can be used to quickly remove devices from an INSTEON scene.
Cross-Linking Two INSTEON Devices Cross-Linking devices allow you to track the on/off status of the load on all Linked INSTEON Responders. For this example we will use a primary device controlling the load and one secondary device in a virtual 3- way.
SwitchLinc will beep Restoring Power to SwitchLinc Timer SwitchLinc stores all of its settings, such as Links to other INSTEON devices, On-Levels/Ramp Rates, etc., with non-volatile memory. Because settings are saved in this non-volatile memory, they will not be lost in the event of a power failure.
SwitchLinc Timer Owner’s Manual Resetting SwitchLinc Timer to its Factory Default Settings The factory reset procedure can be used to clear the SwitchLinc memory of all INSTEON Links, programmed On-Levels and Ramp Rates, X10 addresses, etc. 1) If you are using a Controller to control SwitchLinc, be sure to Unlink it from the Controller. See Unlinking SwitchLinc Timer from an INSTEON Controller.
SwitchLinc Timer Owner’s Manual COLOR OPTIONS FOR SWITCHLINC TIMER You can change the color of the SwitchLinc paddle trim frame to match the décor of any room with an optional paddle color change kit. Color options include light almond (#2400LAL), almond (#2400AL), black (#2400BK), brown (#2400BR), gray (#2400GY), ivory (#2400IV), light almond (#2400LAL), or white (#2400WH).
Important Note about INSTEON Networks; Split Single-Phase vs. 3-Phase Installation For the best INSTEON network performance, be sure you have properly installed at least two Access Points or other dual-band INSTEON devices. INSTEON has only been officially tested in a split single-phase residential environment, but has been known to work in many 3-phase systems, where three dual-band devices are used (one on each phase).
It is possible that some audio-video devices, computers, power strips, or other electrical equipment may attenuate INSTEON signals on the power line. You can temporarily unplug suspected devices to test whether the INSTEON signal improves. If it does, then you can plug in filters that will permanently fix the problem.
Page 22
SwitchLinc, but Re-Link SwitchLinc to the Controller, while the load is SwitchLinc does not SwitchLinc may be Linked on. See Linking an INSTEON Controller to turn on when I send an at its off state. SwitchLinc. ON command from the Controller.
Seller’s liability with respect to this product. For repair or replacement during the warranty period, call the INSTEON Gold Support Line at 800-762-7845 with the Model # and Revision # of the device to receive an RMA# and send the product, along with all other required materials to: Smarthome, Inc.