Errors, warnings, and certain other types of information are displayed via the SB168-ES panel indicators. Messages are also
displayed in the AVS-ESMonitor Error Status field.
Error Messages
When an error occurs the indicators for channels 1 through 16 will flash until the error is resolved, and the IN/OUT [TX]/[RX]
will light and/or flash as shown in the chart below. If repair is required contact your Yamaha dealer.
AVS-ESMonitor
Indicators
No Battery!
on
flash
Critical Battery!
flash
on
flash
Low Battery!
flash
flash
flash
Memory Error! All Memories
were Initialized.
on
flash
flash
Network Hardware Error!
on
flash
Illegal MAC Address! Can-
not Use Network.
flash
on
flash
EtherSound is Not Initialized!
flash
on
on
flash
Different EtherSound Module
Type!
on
on
flash
EtherSound Hardware Error!
on
flash
on
flash
Error Status
The backup battery is almost
completely depleted, and there is
a possibility that the stored set-
tings will be lost.
The backup battery is running
low, and there is a possibility that
the stored settings will be lost.
The backup battery is beginning
to run low.
The internal backup memory was
corrupted and all data has been
initialized.
A malfunction has been detected
in one of the devices connected
to the network.
The MAC address setting has
been corrupted and no communi-
cation can occur via the NET-
WORK terminal.
EtherSound is not initialized.
An unrecognized EtherSound
module has been detected.
An internal EtherSound error has
occurred.
Details
If you turn off the power at this point there
is a possibility that all current settings will
be lost and the unit will be initialized.
Stop using the unit immediately and con-
tact your Yamaha dealer.
If you continue to use the unit there is a
possibility that all current settings will be
lost and the unit will be initialized. Stop
using the unit as quickly as possible and
contact your Yamaha dealer.
If the error reoccurs after restarting the
unit there is a possibility that the backup
battery has been depleted. Contact your
Yamaha dealer.
Contact your Yamaha dealer.
Contact your Yamaha dealer.
EtherSound initialization has failed.
Contact your Yamaha dealer.
The device requires repair. Contact your
Yamaha dealer.
An internal malfunction may have
occurred. Contact your Yamaha dealer.