Troubleshooting - INSTEON TimerLinc 2456S3T Owner's Manual

Plug-in timer
Hide thumbs Also See for TimerLinc 2456S3T:
Table of Contents

Advertisement

TROUBLESHOOTING

Problem
The Status LED on
TimerLinc is not
turning on.
TimerLinc won't Link
or work with a
Controller or
Responder.
TimerLinc is taking a
long time to respond
to a Controller.
Responders are taking
a long time to respond
to TimerLinc.
The load turned on by
itself.
TimerLinc Owner's Manual
Possible Cause
TimerLinc may not be
getting power.
The Controller or
Responder might have
been reset without
Unlinking TimerLinc from
it.
The Controller or
Responder and TimerLinc
may be on opposite power
line phases.
The INSTEON signal may
be too weak.
Large appliances, such as
refrigerators or air
conditioners, may be
producing electrical noise
on the power line.
Other electrical devices,
such as computers,
televisions, or power
strips, may be absorbing
the INSTEON signal.
The Controller may be
sending commands to a
Responder that is no
longer in use. Commands
for the unused Responder
are being resent and
loading down the signal.
TimerLinc may be sending
commands to a
Responder that is no
longer in use. Commands
for the unused Responder
are being resent and
loading down the signal.
Load Sensing may have
been triggered.
Another Controller, a
timer, or stray X10 signals
could have triggered
TimerLinc.
Page 16 of 18
Solution
Make sure TimerLinc is not plugged into a
switched outlet that is turned off.
Re-Link TimerLinc to the Controller or Responder.
Make sure two dual-band INSTEON devices are
properly installed to bridge the two power line
phases.
Add additional INSTEON devices or move around
existing INSTEON devices. All INSTEON devices
act as INSTEON network repeaters.
Install a power line noise filter (#1626-10) to filter
electrical noise and minimize signal attenuation.
Unlink any unused Responders from the
Controller.
HINT: If you are using home automation software,
you can easily check scene membership and
eliminate unnecessary Links.
If the above doesn't work, perform a factory reset
on the Controller.
Unlink any unused Responders from TimerLinc.
HINT: If you are using home automation software,
you can easily check scene membership and
eliminate unnecessary Links.
If the above doesn't work, perform a factory reset.
See Resetting TimerLinc to its Factory Default
Settings.
Disable Load Sensing. See Enabling/Disabling
Load Sensing.
Perform a factory reset. See Resetting TimerLinc
to its Factory Default Settings.