LG LBNG3061YL Service Manual page 43

Ceiling duct air conditioner
Table of Contents

Advertisement

n The problem of missing the connector (OUTDOOR MAIN PCB ASSY)
Connectors
CN-POWER
CN-AC
CN-DC
CN-IPM
CN-Gate 1, 2
CN-GND
CN-FAN
CN-TH
CN-COMP
n The problem of missing the connector (SUB PCB ASSY)
Connectors
CN-UVW
CN-IPM
CN-Gate 1, 2
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Condition
• Malfunctions outdoor unit.
OPEN
• Stop compressor and outdoor fan.
• Malfunctions outdoor unit.
• Stop compressor and outdoor fan.
OPEN
• The operation LED blinks 10 times.
• Malfunctions outdoor unit.
OPEN
• Stop compressor and outdoor fan.
• The operation LED blinks 10 times.
• Malfunctions inverter circuit.
OPEN
• Stop compressor and outdoor fan.
• The operation LED blinks 8 times.
• Malfunctions inverter circuit
OPEN
• The operation LED blinks 9 times.
• Malfunctions EMI /EMS
OPEN
OPEN
• Malfunctions fan.
OPEN/SHORT
• The operation LED blinks twice.
• The LED01K blinks 10 times.
• Continue Comp. operation.
OPEN/SHORT
(when the discharge pipe TH opens)
• Stop Comp. operation
(when the discharge pipe TH shorts)
Condition
• Stop compressor.
OPEN
• Malfunctions inverter circuit.
OPEN
• Stop compressor and outdoor fan.
• The operation LED blinks 8 times.
• Malfunctions inverter circuit
OPEN
• The operation LED blink 9 times.
- 43 -
Problem (error mode)
Problem (error mode)
LGE Internal Use Only