LG LBNG3061YL Service Manual page 41

Ceiling duct air conditioner
Table of Contents

Advertisement

When compressor does not operate normally.
Trouble 5-4
n DC Low Voltage Error (Error Code ⑩ )
Is the LCD of wired remote controller show
'CH10'?
Is the connecting state of connectors in
outdoor PCB Ass'y right?
(CN-DC, CN-AC)
Is the voltage of capacitor over 187Vdc?
Is the connecting state of wires in outdoor
unit?
Replace the PCB Ass'y.
• Main PCB Ass'y (Outdoor)
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
YES
NO
YES
NO
YES
NO
YES
- 41 -
Reconnect the connector.
Check the wiring state.
Check the electrical wiring diagram (Colors)
LGE Internal Use Only

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lbug3061yl

Table of Contents