Honda EX350 Owner's Manual page 22

Honda generator owner's manual
Hide thumbs Also See for EX350:
Table of Contents

Advertisement

l
Never lean over the battery when making connections.
l
Never attempt to charge a frozen battery. The battery
could
rupture and
explode.
If you suspect that a battery may be frozen, remove the vent
caps and check the fluid. If there seems to be no fluid, or lf
you see ice,
do not attempt to charge the battery untif the fluid thaws,
CAUTION:
s Be careful to connect
the chsrglng
cabfer to the correct battery
and
generator terrnlnals fposltive to poshfve snd negatfve to negative).
If the
charging cables am connected
poshfve to negstfve, It may cause serious
battery or generator damage.
l
Do not attempt
to start an eutomobffe
engine with the generator
still
connected
to the bettery;
thfs may dsmage the generator.
NOTE:
l
The DC terminals may be used while the AC power is in use if the AC
load does not exceed 250 VA.
l
if the DC circuit becomes overloaded it will trip the circuit breaker (green
button
will pop out). If this happens, wait a few minutes before pushing
the circuit breaker button
to resume operation.